Reference Manual
Chapter
4
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
179
Communication
Enable Ethernet
This tool handles transmission of result values and images from the device to PC via the
Ethernet port. Input parameter
Status
controls if the transmission will be enabled or di-
sabled. Transmission via Ethernet port = enabled is the default setting.
If
Status = false
transmission will be disabled. In this case the 'Display' tool will not be
updated with current result values and no image will be shown.
If
Status = true
transmission will be enabled again. After enable the transmission again it is
recommended to include a 'Wait' tool with a delay of at least 1 ms in the step program
before using tools that need result values or images. This ensures that the values will be
available for the following tool.
Input Parameters
01 = Status
False
Disable transmission of result values and images from
the device to PC via Ethernet port.
True
Enable transmission of result values and images from
the device to PC via Ethernet port.
Returned Values
None