Locating Shapes (tips and tricks)
Locate and inspect relative to
the located shape
Shape Locator
Transform ROI
A ROI defined in the reference image is moved and rotated
to the position of the located shape.
Teach using external operator
interface
ROI step
An arbitrary shaped ROI defined in the step program.
Add Shape Runtime
The reference shape is created during runtime by specify-
ing a source image and the ROI specified previously.
Shape Locator
Get Shape, Transform Image or Transform ROI