Reference Manual
Chapter
4
IVC-2D
©
SICK AG • Advanced Industrial Sensors • www.sick.com • All rights reserved
105
Measure
12 = Fill Holes in Blobs
If
enabled
, a blob is defined as all pixels
inside its external perimeter. Internal holes are
then considered part of the blob.
If
disabled
, holes will be kept and the blob
will only consist of pixels with original values in
range.
13 = Sort By
Blobs can be sorted according to:
-
Area
-
Horizontal position
(of centroid)
-
Vertical position
(of centroid)
-
Distance to sorting point
-
None
(unsorted)
This option is used together with
Sorting order
to determine in which order to store the blobs.
For example, if sorting the blobs by area in
descending order, the largest blob is num-
bered 0, the second largest is number 1m etc.
If you want to find only the largest blob you can
thus sort by descending area and only analyze
the first blob (with index 0).
14 = Sorting Order
Choose
Ascending
(smallest first) or
De-
scending
(largest first). Use in conjunction
with
Sort by
to determine in which order to
store the blobs.
15 = Sorting Point X
X position of sorting point. Only used when
sorting by
Distance to sorting point
in the
Sort by
option.
16 = Sorting Point Y
Y position of sorting point. Only used when
sorting by
Distance to sorting point
in the
Sort by
option.
17 = Table Index
Blob centroid and blob area can be stored in
the table. Defines where in the table to start
saving blobs.
18 = Max Blobs in Table
Maximum number of blobs to store in the
table. All blobs are stored internally and can be
accessed by the Blob analyzer tool even if no
blobs are stored in the table. Note, however, if
you use the interactive setup to configure your
blob finder step, you will need to use the table
to store blobs if you want to display the list of
blobs beneath the preview window.
Returned Values
01 = Number of Found Blobs
The amount of blobs found.
02 = Low Threshold Used
The lower threshold used when looking for
blobs.
03 = High Threshold Used
The upper threshold used when looking for
blobs.
ERROR CODES
8200
Too many blob candidates are found. Please adjust the thresholds to limit
the number of small blobs.