Communication
Communication Setup
The Communication setup tool is used for specifying which parameters the device should
publish and subscribe to, using either the Ethernet/IP or the OPC protocol.
This tool only specifies the parameters that should be read from or written to the network.
The actual reading and writing of values occurs when a 'Communication Read/Write' tool is
executed.
The Communication setup tool can be used several times in a program, and it is possible
to change the definition of an already specified parameter. For example, if one Communi-
cation setup tool defines that the value from table row 1 should be published as a certain
parameter, and another Communication setup tool defines that table row 2 should be
published as the same parameter, the actual content of the parameter depends on which
Communication setup tool that was executed last.
Input Parameters
None.
This tool is set up by using the interactive setup, which is opened by double-clicking the
Setup button. See “Communication Setup” on page 223 for more information on the
interactive setup.
Returned Values
None.
Error Messages
Err. = 8101
There is a syntax error in the definition of the assembly.
The Emulator does
not emulate this
tool. See section
Handling the
Emulator for more
information.