Troubleshooting
measurement loop of the program. An error code will be returned when the tools are
executed by F5/F8 if the amount of dead space exceeds the threshold.
The threshold is specified as (
amount of dead space
)/(
amount of dead space
+
free
space
) in percent. The functionality for automatic defragmentation can be disabled by
setting the threshold to -1. The lower limit for the threshold is set to 20%, and the upper
limit is set to 80%. The reason for not allowing less than 20% is that the defragmentation
shall not be performed too often. The default value for the threshold is set to 50%.
If the automatic defragmentation is enabled, the camera may perform a defragmentation
of the flash disk when powered up. During this operation, the function LED is set to yellow.
Note that the time to start the camera will in this situation be longer than usual.
6.3
Running IVC Studio
Online help window
cannot be closed
Adobe Acrobat may be blocked by a dialog box saying that it is about
to check for updates. This dialog box is placed under the window with
the online help, making it impossible to close.
Solution
Turn off Acrobat’s function for automatically checking for updates:
1. Start
Acrobat.
2. Choose
Edit
Æ
Preferences
from Acrobat’s main menu.
The
Preferences
dialog box is displayed.
3. Click
on
Updates
in the list to the left.
4.
Acrobat 5 & 6:
Choose Manually
from the
Check for Updates
menu.
Acrobat 7:
Select
Do not automatically check for critical
updates
.
5. Click
OK
to close the Preferences dialog box.
6.4
Debugging Step Programs
The results of
previous steps are
lost during editing
and debugging
The entire contents of the step program are transmitted to the
camera when the step program name is clicked in the tree-view. If
this is done during editing of the step program, the results from
previous steps, e.g. ROI:s, may be lost.
Solution
Execute the step again to restore the result in the camera.
6.5
IVC Emulator
The IVC Emulator
cannot be closed
from IVC Studio
If the IVC Emulator is enabled while the active network is changed in
IVC Studio, it is not possible to disable the emulator from IVC Studio.
Solution
The emulator must be terminated using the Task Manager.
1.
Open
Task Manager
(e.g. by pressing Ctrl+Alt+Del)
2.
In the tab Processes, select
IVCEmulator.exe
in the column
Image Name
.
3.
Click
End Process
4.
Click
Yes
in the dialog with the warning message.
The IVC Emulator
is not visible in
IVC Studio
Some VPN clients and firewalls block the network traffic for the
emulator.
Solution
Contact your IT department for a solution how to configure your VPN
client or firewall in a safe way.