Electrical installation
5.4
Preparations for electrical installation
5.4.1
Requirements for the host interface
The host interface of the CLV can be operated as an RS 422/485 or an RS 232 interface.
shows the recommended maximum cable lengths as a function of the selected
data transfer rate.
¾
To prevent interference, do not lay the cables parallel with power supply and motor
cables over long distances, e. g. in cable ducts.
5.4.2
Supply voltage
The CLV requires a power supply of 18 to 30 V DC for operation without a heater and
24 V DC +20 %/–10 % for operation with a heater (each functional extra-low voltage in
accordance with IEC 364-4-41). The functional extra-low voltage can be generated by using
a safety isloating transformer pursuant to IEC 742.
The power consumption of the individual types is as follows:
Power-up delay
The selected device number (default: 1) affects the power-up delay of the device. This is
useful if a large number of CLVs (e. g. in the SICK network) are to be supplied from one
power source.
contains a list of the available intervals.
Pin
Signal
Function
RS 232
Up to 19,200 bd
38 400 to 57,600 bd
Max. 10 m (32.8 ft)
Max. 3 m (9.84 ft)
RS 422/485
1)
Max. 38,400 bd
Max. 57,600 bd
Max. 1 200 m (3 936 ft)
Max. 500 m (1 640 ft)
1) with suitable line termination according to specifications
Table 5-7: Maximum cable lengths between the CLV and host
Type
Voltage
Scanning method
Heater
Power consumption
1)
Connection
module
CLV 480-0010/-2010/-6010
18 to 30 V DC
Line scanner
No
11 W (typ.)/max. 16 W
AMV/S 60 or
CLV 480-1010/-3010/-7010
18 to 30 V DC
Line scanner with
oscillating mirror
No
13 W (typ.)/max. 18 W
AMV 30-071 or
BMV/BMH 10 or
BMS 20
CLV 480-0011/-2011/-6011
24 V DC
Line scanner
Yes
75 W (typ.)/max. 90 W
AMV 100/200
CLV 480-1011/-3011/-7011
+20 %/–10 %
Line scanner with
oscillating mirror
Yes
75 W (typ.)/max. 100 W
1) switching outputs not connected
Table 5-8: Power consumption of the CLV
Device number GN
Power-up delay
Device number GN
Power-up delay
1; 11; 21; 31
0 ms
6; 16; 26
2,000 ms
2; 12; 22
400 ms
7; 17; 27
2,400 ms
3; 13; 23
800 ms
8; 18; 28
2,800 ms
4; 14; 24
1,200 ms
9; 19; 29
3,200 ms
5; 15; 25
1,600 ms
10; 20; 30
3,600 ms
Table 5-9: Power-up delay as a function of the device number GN