Electrical installation
5.2
Electrical connections and cables
The electrical connections on the CLV consist of two 15-pin D Sub HD connections on the
housing, one plug, and one socket.
These connections are used to route the following interfaces:
•
Three serial data interfaces (host interface, CAN interfaces 1 and 2, terminal interface)
•
Six switching inputs (external reading pulse and multifunctional inputs)
•
Four switching outputs (for result status function, for connecting to a PLC for example)
•
Power supply
5.2.1
Wire cross-sections
CLV without heater:
¾
All connections must be wired with copper cables with a minimum wire diameter of
0.15 mm
2
(approx. 26 AWG)!
CLV with heater:
¾
Connect the power supply terminals (Pin 1/Pin 5) using copper wires with a minimum
cross-section of 0.75 mm
2
(approx. 20 AWG) at a maximum length of 10 m (32.8 ft)!
5.2.2
Prefabricated cables (overview)
For technical data on the cables, see
Chapter 10.12.4 Cables, external parameter memo-
ries and plug cover, Page 10-53
.
CLV
Type
Temperature
range
Connection
module
Optional
cable
Length
Type
CLV
without
heater
0 to +40
°
C
(+32 to
+104
°
F)
AMV/S 60
2 x No. 2 020 302 or
1 x No. 2 020 307
3 m (9.84 in)
3 m (9.84 in)
Connecting cable (plug/socket)
Ext. parameter memory with 2 cables
(plug/socket)
BMV/BMH 10
Bus Connec-
tion Module
1 x No. 2 020 307 or
1 x No. 2 021 298
3 m (9.84 in)
3 m (9.84 in)
Ext. parameter memory with 2 cables
(plug/socket)
Connector cover to connector cover
AMV 30-071
2 x No. 2 020 302 or
1 x No. 2 020 307
3 m (9.84 in)
3 m (9.84 in)
Connecting cable (plug/socket)
Ext. parameter memory with 2 cables
(plug/socket)
BMS 20
Interbus-S
1 x No. 2 020 264 +
1 x No. 2 020 265 or
1 x No. 2 020 308
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
Connecting cable with plug/open end
Connecting cable with plug/socket
Ext. parameter memory with 2 cables
(plug/open end)
Non-Sick
Power pack
1 x No. 2 020 303 +
1 x No. 2 020 264 or
1 x No. 2 020 981 or
1 x No. 2 021 267
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
Connecting cable with socket/open end
Connecting cable with plug/open end
Ext. parameter memory with 2 cables
(open ends)
Connector cover with 2 cables (open ends)
CLV
with
heater
– 35 to +35
°
C
(–31 to
+95
°
F)
AMV 100
1 x No. 2 021 298 or
1 x No. 2 021 689 or
1 x No. 2 027 543
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
Connector cover to connector cover
Ext. parameter memory to connector cover
Ext. parameter memory to connector cover
with wires for CAN interface 1 (IN/OUT)
AMV 200
2 x No. 2 021 298 or
2 x No. 2 021 689 or
2 x No. 2 027 543
3 m (9.84 in)
3 m (9.84 in)
3 m (9.84 in)
Connector cover to connector cover
Ext. parameter memory to connector cover
Ext. parameter memory to connector cover
with wires for CAN interface 1 (IN/OUT)
Non-Sick
Power pack
1 x No. 2 021 267
3 m (9.84 in)
Connector cover with 2 cables (open ends)
Table 5-2: Cables for connecting the CLV