Chapter
10
Operating Instructions
CLV 480 Bar Code Scanner
10-40
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 080/O824/10-02-2005
Appendix
4.
To return to Reading mode, click on the R
EADING
MODE
option field.
The "Device Ready" LED lights up.
Note
The parameter values directly changed with command strings in the CLV are registered and
shown only after the parameter set is uploaded from the CLV.
A list of command strings, is available on request.
Outputting command strings for all the parameter settings
You can output a list of all the parameter settings configured with CLV-Setup in ASCII format.
To do so, proceed as follows:
1.
In the menu bar, choose E
XPORT
P
ARAMETERS
under CLV 480.
Starting from the default settings, CLV-Setup collects all the command strings required
to parameterize the default configuration and customized settings.
The S
ELECT
FILE
NAME
FOR
PARAMETER
EXPORT
dialog box is displayed.
2.
Enter a file name and click the S
AVE
button.
CLV-Setup saves the data as a text file in the directory shown.
You can then open this text file using any Windows text editor.
If the commands are sent from the host/PLC to the CLV for configuration, note that "3 EEW"
has to be sent as the last command to ensure that they are permanently transferred to the
CLV (EEProm).