Troubleshooting
8.3
Error messages
The CLV outputs coded error message (number combinations) via the
terminal interface
only.
contains a list of the messages.
Displaying messages:
To display the messages on the PC, proceed as follows:
¾
Click
in the toolbar.
The Terminal Emulator is launched.
CLV-Setup logs the error messages automatically in a file (sys_msg.log).
8.3.1
CLV without external parameter memory
Message
Meaning
Possible cause
Remedy
"CLV SYS-Failure: xxx"
The CLV has diagnosed a
system error.
The "Device Ready" LED does not
light up or extinguishes.
The system is restarted.
Error key:
1
)
011
Data error (RAM)
012
Address error (RAM)
013
RAM to small
051
Speed out of tolerance
(mirror wheel)
061
Mirror interval out of
tolerance
071
Error: laser shutter
091 to 095 Error: focus control
101 to 118 Error: external parameter
memory
130
Amplifier error
131
Background profile invalid
132
Center position CP 50
implausible
133
Brightness overflow
201 to 215 DSP error
If the error occurs again after
the CLV is restarted, contact
the SICK Service depart-
ment.
1) Deactivate the CAN interface to suppress error numbers above 300 (not relevant in stand-alone mode).
To do so, upload the parameter set from the CLV using CLV-Setup, choose the CAN I
NTERFACE
tab and deactivate the function in the CAN I
NTERFACE
F
UNCTION
section.
Download the parameter set to the CLV!
Table 8-1: Error messages output on the terminal interface