Technical data
9.2
Data sheet CLV 480-1010 bar code scanner
Technical data as CLV 480-0010 with the following exceptions:
9.3
Data sheet CLV 480-0011 bar code scanner
Technical data as CLV 480-0010 with the following exceptions:
Enclosure rating/protection class
IP 65
3)
(to DIN 40 050)/class 3(to VDE 0106/IEC 1010-1)
EMC/vibration/shock tested
to EN 61000-6-2, 61000-6-3/to EN 60068-2-6/to EN 60068-2-27
Weight
approx. 1.5 kg (approx. 3.3 lb)
Ambient operating/storage temperature
0 to +40
°
C/–20 to +70
°
C (+32 to +104
°
F/–4 to +158
°
F)
Max. rel. humidity
90 %, non condensing
Color
SICK blue (RAL 5012)
3) With plug cover or plug cover with parameter memory
Type
CLV 480-0010
Table 9-1: Technical specifications of the CLV 480-0010 (contd.)
Type
CLV 480-1010
Design
line scanner with oscillating mirror
Reading window
side
Angle of emergence
105
°
(center position CW = 50)
Trigger source for focus control
also: oscillating mirror reversal points
Useful aperture angle
max. 50
°
Oscillating mirror functions
permanent (variable position)/oscillating (amplitude per DC variable or fixed)/One-Shot
1)
Oscillating frequency
0.2 to 4 Hz
Max. angle of deflection
max.
±
20
°
(
±
40 CW), (set with software)
Reading ranges
see
Deflection ranges
see
Operating voltage/power consumption
18 to 30 V DC pursuant to ICE 364-4-41/ typically 13 W, max 18 W
Weight
approx. 2.2 kg (approx. 4.84 lb)
1)
One-Shot: one-off oscillating movement per reading pulse (start position and velocity can be selected for forward and return phase)
Table 9-2: Technical specifications of the CLV 480-1010
Type
CLV 480-0011
Design
line scanner with heater
Switching on function/temperature graph
Chapter 10.4 Optional heating, Page 10-26
Power-on delay
35 to 40 min (at 24 V DC and min. ambient operating temperature –35
°
C (–31
°
F))
Operating voltage
24 V DC +20 % /–10 % pursuant to ICE 364-4-41
Power consumption
typically 75 W, max 90 W
Required cross-section
min. 0.5 mm
2
(20 AWG), for power supply
Weight
approx. 1.5 kg (approx. 3.3 lb)
Ambient operating/storage temperature
–35 to +35
°
C/–20 to +70
°
C (–31 to +95
°
F/–4 to +158
°
F)
Table 9-3: Technical specifications of the CLV 480-0011