Chapter
8
Operating Instructions
CLV 480 Bar Code Scanner
8-8
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 080/O824/10-02-2005
Troubleshooting
F
The C
HECK
M
IN
. N
UMBER
OF
C
ODES
function is active.
The number of valid codes detected by
the CLV in Reading mode is less than
that specified under N
UMBER
OF
C
ODES
:
M
INIMUM
.
Instead of the code contents, it outputs
the defined error string in the quantity
defined under N
UMBER
OF
C
ODES
:
M
INIMUM
One object in a set of objects with a
constant number of codes, for example,
contains fewer codes than defined in
the application.
This message is used to indicate errors
on the objects (e. g. check whether
objects are homogeneous: mix with
incorrect objects).
Value Meaning
Possible
cause
Remedy
Table 8-4: Meaning of the ST error status in the reading result (contd.)