Operating Instructions
Chapter
6
CLV 480 Bar Code Scanner
8 010 080/O824/10-02-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-27
Operation
Fig. 6-6:
Reading result of the terminal interface: structure for Good Read
Good Read:
TT=_ _380 ms
MG=_52 % n=_1 AK=1
LS= _ _ _0 FL= _ _ _0 SB= _ _0 MB= _ 11 RM= _ _ _0
0123412345
C39 100% ST=0
CL=10 CP=_52 CD=_500 CS=
300 CA=300 CK=999 DI=F
PO=+_14 OW=+_ _0 FC=_500 CX=_913 CY=_612 CZ=1408 ON= _ _ _0
MW= _ _40 VL= _ _ _0 CI= _ _0
With:
1st. line:
TT
=
Duration of the reading interval (ms)
MG
=
Temporal mean value of the identification quality (%)
n
=
Number of detected bar codes
AK
=
No. of the used distance configuration
2nd. line:
LS
=
Special parameter for SICK-Service
FL
=
Special parameter for SICK-Service
SB
=
Special parameter for SICK-Service
MB
=
Special parameter for SICK-Service
RM
=
Special parameter for SICK-Service
3rd. line:
0123412345
=
Data contents of the bar code
4th line:
C39
=
ID: Code type Code 39 along
100%
=
Identification quality (%)
ST
=
Read status (ST = 0: Good Read)
CL
=
Code length (number of characters)
CP
=
Code position
CD
=
Code distance (radial measured)(mm)
CS
=
Code reliability
CA
=
Scan effort
CK
=
Code continuity
DI
=
Decoding direction
(F = in scanning direction, R = against scanning direction)
5th line:
PO
=
Exact code position (3-digit for tracking) (scale factor: 0.1
°)
OW
=
Exact oscillating angle (3-digit for tracking) (scale factor: 0.1
°)
FC
=
Current focus position (4-digit for tracking) (mm)
CX
=
X-coordinate of bar code (for OTS in transport direction)
CY
=
Y-coordinate of bar code (for OTS across to transport
direction)
CZ
=
Z-coordinate of bar code (for OTS from above directly)
6th line:
MW
=
Modul width
VL
=
Velocity
CI
=
Special parameter for SICK-Service
Fig. 6-7:
Reading result of the terminal interface: structure for No Read
No Read:
TT=_ _ 360 ms MG=_51 % n=_0 AK=1
LS= _ _ _0 FL= _ _ _0 SB= _ _0 MB= _ _1 RM= _ _ _0
no code!
With:
1st. line :
TT
=
Duration of the reading interval (ms)
MG
=
Temporal mean value of the identification quality (%)
n
=
Number of codes detected
AK
=
No. of the distance configuration used
2nd. line:
LS
=
Special parameter for SICK-Service
FL
=
Special parameter for SICK-Service
SB
=
Special parameter for SICK-Service
MB
=
Special parameter for SICK-Service
RM
=
Special parameter for SICK-Service
3rd. line:
no code!
=
No. bar codes found!