Electrical installation
Connection cable no. 2 020 264 ("I/0" connection)
15-pin D Sub HD plug and open cable end
b) Connecting the CLV with external parameter memory no. 2 020 981
CLV without heater:
¾
Cover the "Host/Term" and "I/O" connections on the CLV with the connector cover (pa-
rameter memory) no. 2 020 981. Connect the free cable ends accordingly. The wire
color assignments are shown in
and
.
CLV with heater:
Available on request.
Pin
Signal
Wire color
1
1)
V
S
Red
2
IN 1
White
3
Sensor
Brown
4
Result 1
Violet
5
GND
Blue
6
IN 0
Green
7
IN 2
Yellow
8
Result 2
Grey
9
INGND
Black
10
Result 3
Grey-pink
11
IN 3
Red-blue
12
IN 4
White-green
13
I2C SDA
Brown-green
14
I2C SCL
White-yellow
15
Result 4
Yellow-brown
–
Shield
Orange
1) Pin 1 is jumpered with Pin 1 of the "Host/Term" connection in the CLV