Chapter
6
Operating Instructions
CLV 480 Bar Code Scanner
6-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 080/O824/10-02-2005
Operation
If the "CLV-Setup" program does not recognize parameters transferred during the upload, it
outputs a warning message. Unknown parameters can be edited in the E
XTRAS
tab by
following the conventions for command strings. When the parameter set is then saved, the-
se parameters are also saved.
Transferring and saving a complete CLV parameter set (download)
1.
Click
in the toolbar or press [F4] key.
The "Device Ready" LED is extinguished.
CLV-Setup copies the parameter set to the RAM of the CLV. The D
OWNLOAD
PARAMETERS
dialog box with the storage options is then displayed.
P
ERMANENT
: CLV-Setup copies the parameter record to the RAM
and
to the EEPROM of
the CLV.
T
EMPORARY
: CLV-Setup copies the parameter record to the RAM only. The changes are
lost when the CLV supply voltage is switched off.
2.
Confirm the dialog box with the desired storage option.
The "Device Ready" LED lights up again.
The new parameter set is stored in the CLV either permanently or temporarily dependent of
the selected option.
CLV with external parameter memory
If the parameter set was downloaded and stored
permanently
, CLV-Setup opens a further
dialog box for adjusting the parameter set in the external memory, if the start option is set
to S
TART
WITH
EXTERNAL
PARAMETERS
.
¾
Choose the C
OPY
NOW
INTERNAL
PARAMETER
SET
TO
EXTERNAL
MEMORY
option.
CLV-Setup then instructs the CLV to copy the new parameter set to the external
memory. The "Device Ready" LED lights up again.
The internal and external parameter sets are now identical.
Chapter 10.3.5 Adjusting the parameter set in the external parameter memory af-
ter it has been downloaded to the CLV, Page 10-24
Saving a parameter set in CLV-Setup
1.
To save the modified parameter set as a new configuration file in CLV-Setup, or to over-
write an existing file, choose F
ILE
and S
AVE
AS
.
The F
ILE
SAVE
AS
dialog box is then displayed.
2.
Enter the file name in the dialog box (file name extension "*.scl") and confirm the entry.