4.2.4
Replacing the laser warning label
If necessary, replace the GB/US laser warning label with the required language (
).
The device is delivered with a set of laser warnings in:
•
German/US laser warning and
•
French/US laser warning
See also
Chapter 2.3 General safety instructions and protection measures, Page 2-2
.
4.2.5
Selecting the mounting location
When you select the mounting location, the distance between the CLV and the host and
between the CLV and the bar code are extremely important.
Distance between the CLV and the host
The CLV can be mounted at a maximum distance of 1,200 m (3,937 ft) from the host
without a connection to the SICK network or a bus. In practice, however, the distance de-
pends on the physical configuration of the host interface and the data transfer rate (see
).
Distance between the CLV and the AMV/S 60 Connection Module
The AMV/S 60 Connection Module should not be located further than 10 m (32.8 ft) from
the CLV, since the "CLV-Setup" program on the PC accesses the terminal interface (RS 232)
of the CLV via this module.
Fig. 4-1:
Line scanner: replacing the laser warning labels
Supplied laser warnings: