Troubleshooting
8.3.3
Messages for errors accessing the external parameter memory
The CLV outputs further error messages, in addition to the general error messages in
Chapter 8.3.1 CLV without external parameter memory, Page 8-2
,
if problems arise when
the external parameter memory is accessed.
Message
Meaning
Possible cause
Remedy
1.
"error: access to external
parameters not successful,
internal parameters
loaded"
(Error type: 104, 105,
106, 111, 112,115)
•
Start option: S
TART
WITH
E
X
-
TERNAL
P
ARAMETERS
.
The CLV has
not
loaded the
external parameter set. In-
stead, it has loaded the inter-
nal parameter set to its RAM.
The CLV, however, does not
output data on the host in-
terface.
•
Start option: S
TART
WITH
C
OPY
I
NTERN
–> E
XTERN
.
The CLV was
not
able to copy
the internal parameter me-
mory. It has loaded the inter-
nal parameter set to its RAM.
The external parameter memory is
defective.
Repeat the startup procedure. If
the error is still present, contact
the SICK Service department.
2.
"error: external parameter
memory full,
internal parameters
loaded"
(Error type: 108)
Start option: S
TART
WITH
C
OPY
I
NTERN
–> E
XTERN
.
The CLV was
not
able to copy
the internal parameter memory.
It has loaded the internal pa-
rameter set to its RAM.
The internal parameter set is too
large for the external memory
(memory is full).
Contact the SICK Service depart-
ment.
3.
"error: external parameters
not valid for device,
internal parameters
loaded"
(Error type: 116)
Start option: S
TART
WITH
E
XTER
-
NAL
P
ARAMETERS
.
The CLV has
not
loaded the
external parameter set. Instead,
it has loaded the internal pa-
rameter set to its RAM.
The
CLV, however, does not out-
put data on the host interface.
The parameter set in the external
memory is not from a CLV 480.
Use the correct external para-
meter memory or overwrite the
current one.
4.
"error: no external para-
meter memory connected,
internal parameters
loaded"
(Error type: 102)
•
Start option: S
TART
WITH
E
X
-
TERNAL
P
ARAMETERS
.
The CLV has
not
loaded the
external parameter set. In-
stead, it has loaded the inter-
nal parameter set to its RAM.
•
Start option: S
TART
WITH
C
OPY
I
NTERN
–> E
XTERN
.
The CLV was
not
able to copy
the internal parameter set to
the external memory. It has
loaded the internal para-
meter set to its RAM.
•
External parameter memory not
connected.
•
External parameter memory not
connected.
•
OK if the device is to be oper-
ated without an external pa-
rameter memory.
•
Check whether the memory is
connected correctly (free
wiring: check wire assignment).
•
See
4. Remedy 2nd paragraph
5.
"error: writing parameters
CLV -> EXT,
internal parameters
loaded"
(Error type: 110, 111,
112)
Start option: S
TART
WITH
C
OPY
I
NTERN
–> E
XTERN
.
The CLV was
not
able to copy
the internal parameter set to
the external memory. It has
loaded the internal parameter
set to its RAM
Data transmission error.
Check whether the external para-
meter memory is connected cor-
rectly (free wiring: check wire
assignment).
Repeat the startup procedure. If
the error is still present, contact
the SICK Service department.
Table 8-3: Messages for problems accessing the external parameter memory