Appendix
10.10 Special applications and procedures
10.10.1 Auxiliary input via the terminal interface
If the CLV cannot read a bar code in Reading mode (e. g. if there is no bar code on the ob-
ject), the data content of the bar code can be sent subsequently to the host by using the
"Auxiliary input" function. In this way, the sequence of reading results can be completed if
necessary.
The auxiliary input function uses the terminal interface of the CLV exclusively and features
two options:
•
Manual entry of the data content on the keyboard of a connected terminal or PC
(Terminal Emulation function)
•
Entry of the bar code using a hand-held reader. The data is then forwarded to the CLV
via an internal or external decoder.
shows the basic auxiliary input principle.
The CLV sends the data content of the bar code that it receives via the terminal interface to
the host in the same format as the other reading results on the host interface. Each string
can contain the data from a bar code with a maximum length of 50 characters. The CLV au-
tomatically enters the status ST = 7 if the error status has been enabled for transmission.
The values of the other reading diagnosis data in the data string do not have any signifi-
cance.
To enable the CLV to receive the data content of the bar code on the terminal interface, you
must switch the operating mode on the interface to auxiliary input.
1.
Connect the PC to the
terminal interface
on the CLV using a 3-core RS 232 data cable
(null modem cable) (AMV/S 60: connect the PC to the internal 9-pin "Service" plug).
Chapter 5.5.5 Connecting the CAN interface, Page 5-16
2.
Start CLV-Setup on your PC.
Chapter 10.6.3 Starting CLV-Setup, Page 10-32
3.
Choose the A
UXILIARY
I
NTERFACE
tab.
4.
Choose the A
UXILIARY
I
NPUT
option from the drop-down list.
5.
Download the changes to the CLV.
To do so, click the A
UXILIARY
I
NPUT
option again with the right mouse button and choose
D
OWNLOAD
P
ARAMETER
in the context menu.
CLV-Setup copies the parameter temporary to the CLV.
The terminal interface then operates temporarily in "Auxiliary input" mode.
Fig. 10-34: Auxiliary input via the terminal interface of the CLV
CLV
ST=7
HOST
Data co
Status
Data
contents