Operating Instructions
Chapter
6
CLV 480 Bar Code Scanner
8 010 080/O824/10-02-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-35
Operation
4.
Place the measuring cursor to the right of the first measuring cursor on an edge of the
same signal or of another angle which you are interested in.
The corresponding time and the increment status of the second event are displayed in
the output fields I
NCREMENT
2 and T
IME
2 of the table.
In addition, the time differential and the increment differential are displayed in the D
ELTA
I
NC
and D
ELTA
T
IME
output fields.
Pressing the right mouse button again or scrolling through the display clears both measuring
cursors, and the table disappears.
Placing the second measurement cursor to the left (previous point in time) of the first
measurement cursor is not permitted. If this is attempted, the first measurement cursor
which was set and the table contents are cleared. A cursor cannot be placed outside the
visible range of the plot diagram. An event which cannot be seen can appear in the
measured value table, however.
Printing contents of window:
This function enables the signal conditions which were just displayed in the window to be
printed out as a window with the designations of the plot diagram axes. The printout also
contains the corresponding values of the increment status, time stamp, measured value
table and contents of the data strings of both output fields.
1.
Click the P
RINT
button.
The dialog box for printing is displayed.
2.
Activate the relevant entries and confirm with OK.
Returning to RUN mode:
¾
Click the START button.
CLV-Setup returns to the continuous display of the signal conditions. Any enlargements
of areas of the plot diagram are undone.