background image

 

 

Access-IS  

18 Suttons Business Park, Reading 
Berkshire, RG6 1AZ, United Kingdom 
Tel: +44 (0) 118 966 3333 
Web: www.access-is.com 
Email: [email protected]

 

 

 

Product names 
mentioned herein are for 
identification purposes 
only and may be 
trademarks and/or 
registered trademarks of 
their respective 
companies. 

 

© Copyright 2016 

ALL RIGHTS 
RESERVED

 

 

 

Subject:

 ATR110 Manual

 

Revision:

 1.4

 

Issue Date:

 15/03/2016 

ATR110 

1D/2D Barcode Imager 
(Barcode Only Version) 
 
Product Manual  
 

Summary of Contents for ATR110

Page 1: ... support access is com Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies Copyright 2016 ALL RIGHTS RESERVED Subject ATR110 Manual Revision 1 4 Issue Date 15 03 2016 ATR110 1D 2D Barcode Imager Barcode Only Version Product Manual ...

Page 2: ...vision reception which can be determined by turning the equipment on and off the user is encouraged to correct the interference with one or more of the following measures a Reorient or relocate the receiving antenna b Increase the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the ...

Page 3: ... software 11 3 9 Troubleshooting 11 3 10 Maintenance 11 4 Operating modes 12 4 1 Mode summary 12 4 2 Dumb mode 13 4 3 Host mode 14 4 4 Interactive mode 16 5 Command reference 18 5 1 Basic configuration 19 5 2 Prefix and suffix solutions 20 5 3 ATR110 illumination 21 5 4 Indicator control 23 5 5 Development commands 28 5 6 Triggering 30 5 7 Counter 31 A HID reports 32 A 1 Receive data 32 A 2 Send c...

Page 4: ...user friendly features include bright LED visual indicators and a programmable audio buzzer to confirm successful data capture Its rugged vibration and shock resistant construction with no moving parts enables the reader to withstand years of frontline public use Fast intuitive imager with fixed focal distance Reads barcodes on facedown presentation of mobile device Reads 2D PDF417 and linear barc...

Page 5: ...uirements 5 V DC Electrical interface Serial RS232C and 5 V USB Barcode reading Linear EAN UPC Code 2 of 5 Interleaved 2 of 5 IATA 2 of 5 Code 39 Code 128 2D IATA resolution 792 PDF417 Aztec DataMatrix and QR codes Media supported Reads barcodes from mobile phones tablets and paper MTBF 85 000 hours Approvals CE EMC Class B EN 55022 EN 55024 CE Low Voltage Directive EN 60950 1 IEC 60825 1 LED Safe...

Page 6: ...SB port depending on the product version Note The cable is sealed into the unit to prevent entry of water moisture and dust Standard supplied cable length is 1 8 m Other options are available for pole mounting see page 8 3 2 1 Connection to RS232 Figure 2 Connection to RS232 3 2 2 Connection to a USB port Figure 3 Connection to USB The ATR110 USB obtains power from the USB port To a USB port on th...

Page 7: ...e dimensions of the unit Figure 5 shows the mounting points For optimum performance do not position the ATR110 in direct sunlight Figure 4 ATR110 dimensions rounded to the nearest millimetre 3 3 1 Mounting points Figure 5 ATR110 mounting points Use four M3 screws not provided to mount the unit Maximum insertion depth is 4 mm minimum recommended insertion depth is 2 mm ...

Page 8: ...ATR110 on the pole ensuring that the locating studs on the metal U brackets engage in the two smaller holes in the pole Position the other metal U bracket against the back of the pole and screw the metal brackets together using the four M4 screws removed earlier 7 Replace the plastic cover and screw into place using the two M3 screws To attach the mounting kit to the ATR110 Follow these steps to a...

Page 9: ...he COM port disappears if the unit is unplugged 3 4 2 3 HID Interface Access IS recommends the use of the HID interface for reliability A HID interface recovers properly in the event of accidental disconnects or system power fluctuations a CDC interface may not recover in these situations HID interface using the Access driver Windows only The Access Serial Ports Service driver is fully configurabl...

Page 10: ...R110 to a USB port on the computer 3 6 2 CDC driver This method for USB installation uses the Windows CDC drivers For this method to operate you must install the CDC drivers using the file AccessISCDC inf which you can download from http www access is com gettingstarted The download USB Driver for CDC Mode includes full instructions for use Windows assigns a virtual COM port to the ATR110 device Y...

Page 11: ... resolve the problem For further assistance contact support access is com Alternatively use the Contact Customer Support Team page on the Access IS website Note Do not attempt to disassemble the ATR110 if it does not operate correctly Table 1 Troubleshoot the ATR110 Problem Solution ATR110 not transmitting data to host Check that all cable connections between the ATR110 and host are secure Ensure ...

Page 12: ...vates the Good Read Bad Read indicators on the device The ATR110 waits for up to two seconds for an Accept Reject Ignore command to activate the indicators The host sends an Ignore command to reset the imager if no response from the indicators is required The imager and illumination do not reset until the sensor fails to detect any media for 0 5 seconds 4 1 3 Interactive mode Note This is not the ...

Page 13: ...t Command to ATR Media placed in front of ATR110 Imager activated and barcode scanned Illumination activated as defined in the settings Data sent as configured USB Serial No media detected for 0 5 seconds ATR110 resets Media Detected Imager and Illumination Activated Barcode Read Data Sent to Host Lights Good Read as Settings Instruct Reader Idle Imager and Illumination Deactivated Reader Idle ...

Page 14: ...10 Host mode process flow Media Detected Imager and Illumination Activated Barcode Read Data Sent to Host Imager and Illumination Deactivated Accept or Reject Lights Bad Read as Settings Instruct Lights Good Read as Settings Instruct Reject Accept Reader Idle Reader Idle Ignore Command or No Response within Timeout ...

Page 15: ...d to Host Host Command to ATR Media placed in front of ATR110 Imager activated and barcode scanned Illumination activated as defined in the settings Data sent as configured USB Serial Host decides to accept or reject the data Bad Read AISXXR1 Lights activated as defined in the Bad Read settings No media detected for 0 5 seconds ATR110 resets 4 3 1 3 Ignore Comments ATR Command to Host Host Command...

Page 16: ...me Figure 11 Interactive mode process flow Media Detected Message Sent Requesting Trigger Send Trigger Imager and Illumination Activated Trigger Barcode Read Data Sent to Host Accept or Reject Lights Bad Read as Settings Instruct Lights Good Read as Settings Instruct Imager and Illumination Deactivated Reject Accept Reader Idle Untrigger Force Trigger Reader Idle Force Untrigger Ignore Command ...

Page 17: ...ct the data Good Read AISXXR0 Lights activated as defined in the Good Read settings No media detected for 0 5 seconds ATR110 resets 4 4 1 2 Good Read initiated by host sending trigger command Comments ATR Command to Host Host Command to ATR Host sends a command to trigger the imager This could be due to a second sensor 0x16 0x74 0x0D Imager activated it remains triggered until untriggered or a Goo...

Page 18: ... the keyboard localisation to United States when the device is operating as a USB keyboard To query the current settings including a temporary one Send the six character command with a instead of the parameter and the ATR110 will return the command with the current setting For example 0x16 0x4D 0x0D AISINF queries the device interface and returns the current value To query the stored value Send th...

Page 19: ...00 bps 6 19200 bps 7 38400 bps 8 57600 bps 9 115200 bps AISSCP Set connection parameters for a Serial connection Only used when AISINF is set to 0 Serial 2 0 7N1 1 7N2 2 8N1 3 7E1 4 7E2 5 8E1 6 7O1 7 7O2 8 8O1 AISKBL Keyboard localization this defines the Windows keyboard mapping for correct output of characters Only used when AISINF is set to 2 USB keyboard 0 0 US United States 1 UK United Kingdo...

Page 20: ... if you want to use a single prefix or suffix Table 3 Prefix and suffix commands Command Description Default Parameters Range PREBK299xx Adds a prefix to all barcode symbologies Any two character hex ASCII code can replace xx For example to add STX Start of Text as a prefix use the command PREBK29902 You can add more than one prefix as required xx Hex value PRECA2 Clear all prefixes SUFBK299xx Add...

Page 21: ... 8 0 200 AISOFT Illumination off time Applies to AISILL modes 2 and 3 only adaptive illumination on Each unit is equivalent to 100 milliseconds 8 0 200 AISONM Illumination on mode When set to 0 the timing for the illumination on period is set to a single value AISONT When set to 1 the illumination on period cycles continuously while triggered through the three AISONx values 0 0 Normal adaptive ope...

Page 22: ...aptive illumination modes The illumination modes allow you to configure the device to provide the best lighting to read barcodes on different types of media 0 Off Phone only Adaptive illumination is off The illumination LEDs do not light when you present media to the device 1 Off Paper only Adaptive illumination is off The illumination LEDs light when you present media to the device The LEDs illum...

Page 23: ...uivalent to 100 milliseconds 8 0 200 AISBDS Bad Read duration start Specifies when the Bad Read indicator illuminates 0 0 At Bad Read 1 At media removal AISBIN Bad Read indication stop Specifies when the Bad Read indicator extinguishes 1 0 At media removal 1 Continues after media removal 5 4 2 LED control method options Use the AISLCM command to select the LED control method There are four methods...

Page 24: ...blue or amber and off flashing alternate flashing or constant In Dumb mode the Good Read LED flashes on a successful read overriding any other LED setting Disable this functionality by setting the Good Read indicator duration AISGDT to zero 0 In Host and Interactive modes use AISXXR0 AISXXR1 and AISXXR2 commands to update the status of the ATR110 these commands do not affect the LEDs Use the AISLC...

Page 25: ...LED D For more than one LED add the values For example for Good Read on LEDs A and D use AISGSL9 Note Power and Busy LEDs are only applicable to LED control mode 1 AISGCO AISBCO AISUCO AISPCO Configures the LED colours for Good Read Bad Read Busy and Power indicators 2 1 3 4 0 Off 1 Red 2 Green 3 Amber 4 Blue AISGBA AISBBA AISUBA AISPBA Configures the LED bank for Good Read Bad Read Busy and Power...

Page 26: ...shes alternately with the other LEDs The second character sets the colour Second character LED colour 0 LED off even if set to flash 1 Red 5 Green 9 Amber D Blue LED control direct parameter format example Command AISLCD4141414155555555 This would cause the front LEDs to flash red and the rear LEDs to flash green The front and rear banks would flash alternately 5 4 5 Summary of valid commands Tabl...

Page 27: ...nt to 100 milliseconds 5 0 100 AISGBS Good Beep silence duration Each unit is equivalent to 100 milliseconds 1 0 100 AISGBN Good Beep number of beeps 1 0 5 AISGBV Good Beep volume 2 0 Off 1 Low 2 Medium 3 High AISBBF Bad Beep frequency 0 0 700 Hz 1 1400 Hz 2 2800 Hz AISBBD Bad Beep active duration Each unit is equivalent to 100 milliseconds 4 0 100 AISBBN Bad Beep number of beeps 3 0 5 AISBBS Bad ...

Page 28: ... this flag is set then the TRIG messages from the ATR110 are sent only on media detect and media removed regardless of commands from the host 0 0 Disabled 1 Enabled AISRDS Changes the configuration back to its default values Warning This command resets all parameters to their default values including any values specific to your stored configuration 1 AISFWV Returns the version of the firmware AIS_...

Page 29: ...sor reset is 48 64 112 Table 10 Status LED commands Command Description Default Parameters Range AISLS1 Status LED function 4 0 None 1 Power on 2 Loader 3 Power on and loader 4 Power on except when triggered 16 Brownout detection Diagnostic 32 Brownout reset Diagnostic 48 Brownout status Detection or reset Diagnostic 64 Intelli sensor reset Diagnostic 128 Watchdog reset Diagnostic AISLS2 Status LE...

Page 30: ...NSSMO Sensor maximum on time Each unit is equivalent to 100 milliseconds 600 60 seconds If the infrared sensor detects media for more than the timeout for example because there is a sticker on the glass it is disabled allowing the imager to work in presentation mode 600 0 feature disabled 1 60000 AISTRE Enable document detect trigger Warning This is for advanced users only and modification may cau...

Page 31: ...5 7 Counter These commands display the number of Good or Bad reads made by the device Table 13 Counter commands Command Description Default Parameters Range AISGRC Good Read counter Cannot be reset 0 AISBRC Bad Read counter Cannot be reset 0 ...

Page 32: ...identifier 62 Reserved 63 Data cont d A 1 1 Example HID input reports as sent by the device In this example the decoded barcode contained 60 bytes of data which the device split into two HID reports Note that byte 63 in 0x01 in the first report and 0x00 in the second report indicates whether to expect more data or not In the second packet the remaining 52 bytes of data are set to 0x00 Bit Byte 7 6...

Page 33: ...0x73 s 62 0x00 63 0 0 0 0 0 0 0 0 A 2 Send commands To send commands to the ATR110 use a HID out report with the following structure Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 253 1 Data length 2 Output data up to 62 bytes 63 A 2 1 Example output report to request firmware version Bit Byte 7 6 5 4 3 2 1 0 0 253 1 0x0B 2 0x16 0x4D 0x0D AISFWV1 63 ...

Page 34: ...report with the following structure Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 4 1 Flash Good Read light Green Flash Bad Read light Red Initiate barcode read trigger Prevent barcode read untrigger Note You can only use trigger and untrigger commands in Interactive mode Good Read and Bad Read indicator controls are only available in Host or Interactive modes ...

Page 35: ...age return 14 0E SO Shift out X on 15 0F SI Shift in X off 16 10 DLE Data line escape 17 11 DC1 Device control 1 oft XON 18 12 DC2 Device control 2 19 13 DC3 Device control 3 oft XOFF 20 14 DC4 Device Control 4 21 15 NAK Negative acknowledgement 22 16 SYN Synchronous idle 23 17 ETB End of transmit block 24 18 CAN Cancel 25 19 EM End of medium 26 1A SUB Substitute 27 1B ESC Escape 28 1C FS File sep...

Page 36: ... 49 31 1 One 50 32 2 Two 51 33 3 Three 52 34 4 Four 53 35 5 Five 54 36 6 Six 55 37 7 Seven 56 38 8 Eight 57 39 9 Nine 58 3A Colon 59 3B Semicolon 60 3C Less than or open angled bracket 61 3D Equals 62 3E Greater than or close angled bracket 63 3F Question mark 64 40 At symbol 65 41 A Uppercase A 66 42 B Uppercase B 67 43 C Uppercase C 68 44 D Uppercase D 69 45 E Uppercase E 70 46 F Uppercase F 71 ...

Page 37: ...se Z 91 5B Opening bracket 92 5C Backslash 93 5D Closing bracket 94 5E Caret circumflex 95 5F _ Underscore 96 60 Grave accent 97 61 a Lowercase a 98 62 b Lowercase b 99 63 c Lowercase c 100 64 d Lowercase d 101 65 e Lowercase e 102 66 f Lowercase f 103 67 g Lowercase g 104 68 h Lowercase h 105 69 i Lowercase i 106 6A j Lowercase j 107 6B k Lowercase k 108 6C l Lowercase l 109 6D m Lowercase m 110 ...

Page 38: ...C HEX Symbol Description 117 75 u Lowercase u 118 76 v Lowercase v 119 77 w Lowercase w 120 78 x Lowercase x 121 79 y Lowercase y 122 7A z Lowercase z 123 7B Opening brace 124 7C Vertical bar 125 7D Closing brace 126 7E Tilde 127 7F DEL Delete ...

Page 39: ...ess IS 2016 C Document history Issue Date Description 1 0 05 03 2015 Initial distribution 1 1 05 06 2015 First full release 1 2 21 08 2015 Typographical update 1 3 01 02 2016 Style and content updates 1 4 15 03 2016 Minor changes ...