background image

MR6121E UHF reader user manual

Ver 1.0

)◣

 

Address

Floor 3/5, Block D,Changyuan New  Material Port, No 2 Central 1st Hi-tech Av., Nanshan Shenzhen, P.

R.C.

 

Post

:518057 

   Phone:0755-2654 6392   FAX:0755-2655 3743 

E-mail

[email protected]

 

  Website

www.marktrace.com

 

1

 

MR6121E  

UHF Reader User Manual 

 

 
 
 
 
 
 
 
 

Shenzhen Marktrace Co., Ltd 

 

Summary of Contents for MR6121E

Page 1: ... 5 Block D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 1 MR6121E UHF Reader User Manual Shenzhen Marktrace Co Ltd ...

Page 2: ...057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 2 Dear Customer Many thanks for bought Marktrace device Go through precuts user manual carefully before you operate To make sure Marktrace device work correct Any questions please contact us We welcome your feedback and comments Shenzhen Marktrace Co Ltd ...

Page 3: ...cuments may have no further notice Don t tear up the warranty label or take reader apart to repair by yourself we reject perform warranty duties if this happened Shenzhen Marktrace Co Ltd have trademark right on the trademark which in this user manual and receive legal protection DO NOT make free with theses trademarks Customer Service Center Phone 400 022 3382 0755 2654 6392 2654 4205 Fax 0755 26...

Page 4: ...READER STRUCTURE EXPLANATION 10 3 2 EXPLANATION ON THE READER COMMUNICATION INTERFACE 10 4 QUICK START GUIDE 12 5 READER PARAMETER CONFIGURATION 14 5 1 WEBPAGE CONFIGURATION 14 5 2 DEMO SOFTWARE CONFIGURATION 17 5 2 1 Reader connection 17 5 2 2 Antenna RF Power setting 17 5 2 3 Frequency Setting 18 5 2 4 Working Mode Setting 18 5 2 5 Buzzer LED Setting 19 5 2 6 IP Address Setting 19 5 2 7 GPIO Set...

Page 5: ... technical marktrace com Website www marktrace com 5 6 2 1 ISO18000 6B tag Identify 26 6 2 2 Multi tag user data reading 27 6 2 3 Single tag data reading and read with UID 28 6 2 4 Single tag writing and write with UID 29 6 2 5 Single tag data lock 29 6 2 6 Single tag lock and query 29 7 READER STRUCTION AND INSTALLATION SKETCH MAP 31 8 SECONDARY DEVELOPMENT 32 9 COMMON FAULTS AND EXCLUSION METHOD...

Page 6: ...e with precuts to get power If not may harm the products 3 Falling damage Mind parts damage by device falling if this happens turn off power immediately and connect the distributor or Marktrace customer service center 4 Unusual condition Away from fire If you find unusual odor when you use this products or reader on overheating or emitting smog please power off immediately and drop plug form the p...

Page 7: ...d and write fast reader speed can connect to four antennas etc 1 Accord with ISO18000 6B and ISO18000 6C EPC GEN2 standard 2 Use unique anti collision algorithm has the super multi tag identify ability 3 Have tag identify function and data area read write lock and kill these functions And supply the suit API to customer to do secondary development 4 Multi tag identify ability The MAX reader range ...

Page 8: ...tion and data collecting project As the best performance of this reader the reader are widely use in various RFID system reference application as below 1 Transportation management highway management railway management and container management etc 2 Motor vehicle management can control and manage motor vehicle in Ministry of Public Security or Ministry of Communications 3 Rode and bridge charge man...

Page 9: ...y is 500kHz modulation mode is ASK 3 Trigger working mode Timer and I O can trigger reader Timer interval from 10 990ms I O trigger MAX time is 255s 4 Data pre processing On trigger working mode Tag data can store in cache or output directly 5 Data cache Trigger working mode data cache using FRAM ferroelectric memory which can save data when power down memory capacity is 32KBytes Can save 2200 pcs...

Page 10: ...interface as the output port for data modulation RS232 has 8 data bits format 1 start bit and 1 stop bit no parity bit The default baud rate is 115200 bps The interface supports the reader parameters configuration software upgrading demo program and all functions for series communication with development kit with functions package 2 RJ45 Ethernet Port 100M Ethernet TCP Server Mode It is main mode ...

Page 11: ...S485 interface support RS232 all supported functions 5 Programmable output interface Two sets TTL electrical level programmable output interface 1 2 pin works as Wiegand output interface default is high level 5V one set relay interface 13 14 15 pin relay default status is OFF and COM short circuit 6 Input check port 2 team input check port 7 8 pin can configure as trigger read mode default as Dang...

Page 12: ...ower on connect reader to LAN or PC by network cable 2 In PC open demo software MR6100 Demo V1 0 fill in reader IP address and click Connect to connect reader reader factory default IP address 192 168 1 200 3 After reader connection it will automatically detecting antenna and transmit power query in Setting page selecting detected antenna port green icon and click Set button set corresponding port...

Page 13: ...oor 3 5 Block D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 13 5 Click Stop button to Stop identify operate ...

Page 14: ... 0755 2655 3743 E mail technical marktrace com Website www marktrace com 14 5 Reader parameter configuration 5 1 Webpage configuration Reader connect to LAN through TCP IP port or directly connect PC in PC IE browser input reader IP address reader factory default IP address 192 168 1 200 after running then open WEB page as below Can be configure as below 1 Basic Item configuration ...

Page 15: ...indicating etc 2 Each antenna port RF power can be configurable range 0 31dBm 3 Frequency standard China Frequency US Frequency EU Frequency three type standard hopping frequency selectable 4 Applied mode Favor speed and Favor quantity two mode selectable Favor speed for single tag or small batch tags quick speed read mode Favor quantity for big batch tags read mode 2 Operating mode configuration ...

Page 16: ...e word as unit 6B tag data use byte as unit 5 User filter repeat tag Filter set one slide time window only new data which not show in box can be buffer or direct output 6 Read tag data can be select buffer or directly output data buffer adapt with power down save ferroelectric memory storage capacity 32KBytes when read data length is 12Bytes can store more than 2200pcs tag data 3 output configurat...

Page 17: ...on will be valid only after click left bottom button set button 5 2 Demo software Configuration 5 2 1 Reader connection Click MR6100Demo exe software input reader s IP into the IP input box Default IP 192 168 1 200 Port 100 which is fixed then click connect ICON software information display box will display the reader s parameter on the success connection Below image demonstrate the success connec...

Page 18: ...rt will begin self detection and the connecting Antenna port is on GREEN ICON Disconnecting Antenna port is on RED ICON Only the selected GREEN ICON port s antenna works 4 On Integrated RFID reader and Desktop RFID reader config and set one antenna port for the reader to work 5 2 3 Frequency Setting On MR6100Demo exe software s Setting interface Query Reader s Frequency on Frequency setting menu N...

Page 19: ...p Highway toll Favor Quantity is for the multi and tense tags reading Favor Speed working mode is configurated for the applications e g warehouse logistic 3 If the reader is configurated into Favor speed working mode it s invalid for the Matched EPC tag reading 5 2 5 Buzzer LED Setting 1 On Setting interface s Buzzer LED Setting menu for Querying and Setting Buzzer LED ON OFF Take below image for ...

Page 20: ...Reader automatically reset when set a new IP address and need to reconnect the reader with new IP address 5 2 7 GPIO Setting On Setting interface s Set Out Port menu for the reader output port setting The reader has two sets output port and one set Relay port IO Port0 and IO Port1 are output port with default High level voltage 5V and Low level voltage 0V configurable IO port2 is Relay output port...

Page 21: ...entify 1 On Gen2 EPC Multi Tag interface s Identify menu for the Multi tag identify and click Identify ICON to start the reading EPC code antenna number and tag reading times displayed on the interface info box On the interface bottom displays tag number Peak reading rate Read times total reads Average reading rate and duration reading time Take below image for the reference 2 Click Stop ICON for ...

Page 22: ...s read tag s RESERVE Membank EPC Membank TID Membank USER Membank at the same time The steps are 1 select the reading Membanks 2 select the start reading address and the reading word count EPC tag s unit is word and then click Read ICON to start the Multi tag reading Take below image for the reference 2 Click Stop ICON to stop Multi tag reading at the bottom of the demo software interface display ...

Page 23: ...alue then click Write ICON to encoding the multi tag Take below image for the reference 4 Click Stop ICON to stop the Multi Tag encoding at the bottom of the demo software display the Success encoding tag number and tag encoding duration time 5 In accordance with the EPC Protocol On Multi Tag Read Multi Tag Write EPC Membank s Start reading address and Start encoding address is from the EPC Memban...

Page 24: ...peed working mode tag filter setting is invalid 2 Match setting reader reads and displays only the condition matched tag 3 Mismatch setting Reader doesn t read and display the condition matched tag 4 Empty the input value for cancel the Tag filter rule 5 If setting EPC Membank as the Tag filter rule the valid Word Addr is 2 6 After set the EPC tag filter rule this rule is valid for all EPC tag det...

Page 25: ...bank only can be read and write with Access Password EPC Memban and USER Membank can be encoded with Access Password 4 Lock forever if the tag is set to lock forever it can t be unlock again 6 1 5 EPC Gen2 Tag Read and write with Access Password 1 n Gen2 EPC Single Tag interface s Gen2 Secured Read and Gen2 Secured Write menu for the EPC tag reader and write with Access password Take below image f...

Page 26: ... the Access Password 5 In accordance with the EPC Protocol TID Membank can t be locked Access Password is invalid for TID Membank 6 1 6 EPC Gen2 Tag Kill 1 On Gen2 EPC Single Tag interface s Gen2 Kill menu for the Tag Kill password to kill the tag Take below image for the reference 2 EPC Gen2 tag can t be read and write if the tag is killed 6 2 ISO18000 6B Protocol tag Demonstration 6 2 1 ISO18000...

Page 27: ...ti tag user data reading Put several 6B tags in the radiation range of antenna in the ISO 6B operation interface choose Multi Tag Read to enter into multi tag data reading interface choose the start address of data that you want to read then click Read button to operate multi tag data reading the interface will indicate 8 bytes data from start address antennas numbers and times to be read like fol...

Page 28: ...choose Single Tag to enter into single tag operation interface choose the start address of data you want to read in the ISO Read menu item click Read button to start reading data the interface will indicate the tags data that is read the data length is 8 bytes data from start address 2 When data read with UID it needs to know the UID of the tag first you can set the start address to 0 when query U...

Page 29: ...cept for inputting the single byte data that needs to write it also needs to put the UID number of tag choose the start address that want to write click Write With UID button to write data 6 2 5 Single tag data lock 1 Single Tag operation interface choose the data address you want to lock in the ISO Lock menu item click Lock button to lock data if return ISO Lock tag success in Result column it me...

Page 30: ...ock D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 30 return query result in Result column like Had locked and Not lock ...

Page 31: ...ew Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 31 7 Reader struction and installation sketch map 1 MR6121E integrated reader installation sketch map ...

Page 32: ... P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 32 8 Secondary development User can make secondary development for reader application software if needing We provide SDK which supports VC C JAVA and so on the use of SDK please refer to MR6100 serial reader SDK instruction ...

Page 33: ...n range of antenna is single tag or small amount of tags Invalid tag filter settings make sure the reading mode for reader is multi tag read Unable to refresh the page in the web configuration Clear CGI in the web address or re enter the IP address of the reader and refresh FCC Caution Any Changes or modifications not expressly approved by the party responsible for compliance could void the user s...