background image

MR6100 Serial UHF reader user manual

Ver 1.0

)◣

 

Address

Floor 3/5, Block D,Changyuan New  Material Port, No 2 Central 1st Hi-tech Av., Nanshan Shenzhen, P.

R.C.

 

Post

:518057 

   Phone:0755-2654 6392   FAX:0755-2655 3743 

E-mail

[email protected]

 

    Website

www.marktrace.com

 

 

MR6100 Serial 

UHF Reader User Manual 

 

 
 
 
 
 
 
 
 

Shenzhen Marktrace Co., Ltd 

 

Summary of Contents for MR6100 Series

Page 1: ... 5 Block D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 1 MR6100 Serial UHF Reader User Manual Shenzhen Marktrace Co Ltd ...

Page 2: ...518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 2 Dear Customer Many thanks for bought Marktrace device Go through precuts user manual carefully before you operate To make sure Marktrace device work correct Any questions please contact us We welcome your feedback and comments Shenzhen Marktrace Co Ltd ...

Page 3: ... new documents may has no further notice Don t tear up the warranty label or take reader apart to repair by yourself we reject perform warranty duties if this happened Shenzhen Marktrace Co Ltd have trademark right on the trademark which in this user manual and receive legal protection DO NOT make free with theses trademarks Customer Service Center Phone 400 022 3382 0755 2654 6392 2654 4205 Fax 0...

Page 4: ...2 2 Antenna and power setting 错误 未定义书签 5 2 3 Frequency setting 错误 未定义书签 5 2 4 Working mode setting 错误 未定义书签 5 2 5 Buzzer and LED seeting 错误 未定义书签 5 2 6 TCP parameter setting 错误 未定义书签 5 2 7 GPIO setting 错误 未定义书签 6 DEMO software functions demonstration 错误 未定义书签 6 1 EPC G2 tag operate 错误 未定义书签 6 1 1 Gen2 EPC Multi tag identify 错误 未定义书签 6 1 2 EPC multi tag read and multi tag write 错误 未定义书签 6 1 3 Gen2 ...

Page 5: ...lone with precuts to get power If not may harm the products 3 Falling damage Mind parts damage by device falling if this happens turn off power immediately and connect the distributor or Marktrace customer service center 4 Unusual condition Away from fire If you find unusual odor when you use this products or reader on overheating or emitting smog please power off immediately and drop plug form th...

Page 6: ...Model Description Parameter Photo MR6111E Long range integrated reader 12dBi Gain antenna inside MR6121E Mid range integrated reader 9dBi Gain antenna inside MR6134E Four channel reader Can connect to 1 4 different Gain antennas MR6161E Desktop reader 3dBi Gain antenna inside 2 2 Reader instruction This products has the features like multi protocol compatible multi tag identify multi tag multi are...

Page 7: ...an connect to 1 to 4 same gain and different gain planar antennas via high frequency cable To expand the identify area of tag and reduce the hardware cost for customer The RF power of the antennas can set from 0 to 31dBm in separate 7 Reader will detect antennas when it get power In case to protect antenna port The one has no antenna connect will not send RF power 8 Have RS232 RS485 Weigand TCP IP...

Page 8: ... transfer and vehicle management 5 Logistics and warehouse Management Goods flow warehouse management and the flowing management of mail parcel luggage 6 Productive lines Management Production process fixed Identify or technological process control 2 4 Reader main functions 1 Read tag data Can read multi tag same area and same data length in a same time 2 Write tag Can write the same data length i...

Page 9: ... or output directly 5 Data cache Trigger working mode data cache using FRAM ferroelectric memory which can save data when power down memory capacity is 32KBytes Can save 2200 pcs tag data in 12 Bytes data length 6 Data output Data return by instant messaging Can config RS232 RS485 Weigand TCP IP Relay interface Can config output data length and start address Output data format in ASCII 7 Compatibl...

Page 10: ... tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 10 3 Reader Structure and Interface Explanation 3 1 Reader Structure Explanation 1 MR6134E Four channel reader structure explanation 2 MR6161E Desktop reader structure explanation ...

Page 11: ... data modulation RS232 has 8 data bits format 1 start bit and 1 stop bit no parity bit The default baud rate is 115200 bps The interface supports the reader parameters configuration software upgrading demo program and all functions for series communication with development kit with functions package 2 RJ45 Ethernet Port 100M Ethernet TCP Server Mode It is main mode for connecting communication wit...

Page 12: ...485 interface support RS232 all supported functions 5 Programmable output interface Two sets TTL electrical level programmable output interface 1 2 pin works as Wiegand output interface default is high level 5V one set relay interface 13 14 15 pin relay default status is OFF and COM short circuit 6 Input check port 2 team input check port 7 8 pin can configure as trigger read mode default as Dangl...

Page 13: ...ower adapter to reader and then power on connect reader to LAN or PC by network cable 2 In PC open demo software MR6100 Demo V1 0 fill in reader IP address and click Connect to connect reader reader factory default IP address 192 168 1 200 3 After reader connection it will automatically detecting antenna and transmit power query in Setting page selecting detected antenna port green icon and click ...

Page 14: ... Floor 3 5 Block D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 14 5 Click Stop button to Stop identify operate ...

Page 15: ...FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 15 5 Reader parameter configuration 5 1 Webpage configuration Reader connect to LAN through TCP IP port or directly connect PC in PC IE browser input reader IP address reader factory default IP address 192 168 1 200 after running then open WEB page as below Can be configure as below 1 Basic Item configuration ...

Page 16: ...rd indicating etc 2 Each antenna port RF power can be configurable range 0 31dBm 3 Frequency standard China Frequency US Frequency EU Frequency three type standard hopping frequency selectable 4 Applied mode Favor speed and Favor quantity two mode selectable Favor speed for single tag or small batch tags quick speed read mode Favor quantity for big batch tags read mode 2 Operating mode configurati...

Page 17: ... use word as unit 6B tag data use byte as unit 5 User filter repeat tag Filter set one slide time window only new data which not show in box can be buffer or direct output 6 Read tag data can be select buffer or directly output data buffer adapt with power down save ferroelectric memory storage capacity 32KBytes when read data length is 12Bytes can store more than 2200pcs tag data 3 output configu...

Page 18: ...ation will be valid only after click left bottom button set button 5 2 Demo software Configuration 5 2 1 Reader connection Click MR6100Demo exe software input reader s IP into the IP input box Default IP 192 168 1 200 Port 100 which is fixed then click connect ICON software information display box will display the reader s parameter on the success connection Below image demonstrate the success con...

Page 19: ...ion and the connecting Antenna port is on GREEN ICON Disconnecting Antenna port is on RED ICON Only the selected GREEN ICON port s antenna works 4 On Integrated RFID reader and Desktop RFID reader config and set one antenna port for the reader to work 5 2 3 Frequency Setting On MR6100Demo exe software s Setting interface Query Reader s Frequency on Frequency setting menu there are China Frequence ...

Page 20: ...are two working mode Favor speed and Favor quantity for the query and setting take below image for the reference 2 Favor speed is for single tag or few tags reading with the high speed tag reading rate Favor Speed working mode is configurated for the applications require high speed tag reading rate e g Not stop Highway toll Favor Quantity is for the multi and tense tags reading Favor Speed working...

Page 21: ...OFF Reader automatically reset and need to reconnect the reader 5 2 6 IP Address Setting 1 On setting interface s TCP Parameter Setting menu for querying and setting reader s IP take below image for the reference 2 Reader automatically reset when set a new IP address and need to reconnect the reader with new IP address 5 2 7 GPIO Setting On Setting interface s Set Out Port menu for the reader outp...

Page 22: ... manual Ver 1 0 Address Floor 3 5 Block D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 22 ...

Page 23: ... Identify 1 On Gen2 EPC Multi Tag interface s Identify menu for the Multi tag identify and click Identify ICON to start the reading EPC code antenna number and tag reading times displayed on the interface info box On the interface bottom displays tag number Peak reading rate Read times total reads Average reading rate and duration reading time Take below image for the reference 2 Click Stop ICON f...

Page 24: ...r is read tag s RESERVE Membank EPC Membank TID Membank USER Membank at the same time The steps are 1 select the reading Membanks 2 select the start reading address and the reading word count EPC tag s unit is word and then click Read ICON to start the Multi tag reading Take below image for the reference 2 Click Stop ICON to stop Multi tag reading at the bottom of the demo software interface displ...

Page 25: ...g value then click Write ICON to encoding the multi tag Take below image for the reference 4 Click Stop ICON to stop the Multi Tag encoding at the bottom of the demo software display the Success encoding tag number and tag encoding duration time 5 In accordance with the EPC Protocol On Multi Tag Read Multi Tag Write EPC Membank s Start reading address and Start encoding address is from the EPC Mem...

Page 26: ...r speed working mode tag filter setting is invalid 2 Match setting reader reads and displays only the condition matched tag 3 Mismatch setting Reader doesn t read and display the condition matched tag 4 Empty the input value for cancel the Tag filter rule 5 If setting EPC Membank as the Tag filter rule the valid Word Addr is 2 6 After set the EPC tag filter rule this rule is valid for all EPC tag ...

Page 27: ...Membank only can be read and write with Access Password EPC Memban and USER Membank can be encoded with Access Password 4 Lock forever if the tag is set to lock forever it can t be unlock again 6 1 5 EPC Gen2 Tag Read and write with Access Password 1 n Gen2 EPC Single Tag interface s Gen2 Secured Read and Gen2 Secured Write menu for the EPC tag reader and write with Access password Take below imag...

Page 28: ...out the Access Password 5 In accordance with the EPC Protocol TID Membank can t be locked Access Password is invalid for TID Membank 6 1 6 EPC Gen2 Tag Kill 1 On Gen2 EPC Single Tag interface s Gen2 Kill menu for the Tag Kill password to kill the tag Take below image for the reference 2 EPC Gen2 tag can t be read and write if the tag is killed 6 2 ISO18000 6B Protocol tag Demonstration 6 2 1 ISO18...

Page 29: ...Multi tag user data reading Put several 6B tags in the radiation range of antenna in the ISO 6B operation interface choose Multi Tag Read to enter into multi tag data reading interface choose the start address of data that you want to read then click Read button to operate multi tag data reading the interface will indicate 8 bytes data from start address antennas numbers and times to be read like ...

Page 30: ...ce choose Single Tag to enter into single tag operation interface choose the start address of data you want to read in the ISO Read menu item click Read button to start reading data the interface will indicate the tags data that is read the data length is 8 bytes data from start address 2 When data read with UID it needs to know the UID of the tag first you can set the start address to 0 when quer...

Page 31: ... except for inputting the single byte data that needs to write it also needs to put the UID number of tag choose the start address that want to write click Write With UID button to write data 6 2 5 Single tag data lock 1 Single Tag operation interface choose the data address you want to lock in the ISO Lock menu item click Lock button to lock data if return ISO Lock tag success in Result column it...

Page 32: ... Block D Changyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 32 return query result in Result column like Had locked and Not lock ...

Page 33: ...hangyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 33 7 Reader struction and installation sketch map 1 MR6134E reader struction sketch map ...

Page 34: ...angyuan New Material Port No 2 Central 1st Hi tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 34 2 MR6161E desktop reader struction sketch map 3 MR6134E reader installation sketch map ...

Page 35: ... tech Av Nanshan Shenzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 35 Notice MR6134E can connect with 4 antennas every antennas installs in different position to read tags on goods better 4 MR6111E MR6121E integrated reader installation sketch map ...

Page 36: ...enzhen P R C Post 518057 Phone 0755 2654 6392 FAX 0755 2655 3743 E mail technical marktrace com Website www marktrace com 36 8 Secondary development User can make secondary development for reader application software if needing We provide SDK which supports VC C and so on the use of SDK please refer to MR6100 serial reader SDK instruction ...

Page 37: ...ected well Unable to connect reader make sure the reader IP address is correct make sure the network environment is good Reader is unable to identify tag make sure antenna ports are connected correctly make sure antenna power is not to be 0 No sound when reading tag make sure the buzzer is open Tag with password operation failed make sure that when tag operates with password the radiation range of...