background image

PowerScan™ PM9500 Family

Industrial Cordless Handheld

Area Imager Bar Code Reader

Quick Reference Guide

Summary of Contents for PowerScan PM9500

Page 1: ...PowerScan PM9500 Family Industrial Cordless Handheld Area Imager Bar Code Reader Quick Reference Guide...

Page 2: ...you can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate me...

Page 3: ...es 7 Configure Other Settings 7 Resetting Product Defaults 7 Compatibility with the PowerScan 8000 family 8 Set Date and Time 8 Linking the Reader 9 Link Datalogic RF Devices to Base 9 Power Off 9 Ope...

Page 4: ...ii PowerScan PBT9500 NOTES...

Page 5: ...trol with Datalogic S p A 1 2 Documentation means materials such as user s guides program reference guides quick reference guides manuals or similar mate rials associated with or related to the Datalo...

Page 6: ...transfer of the Datalogic Product absent such agreement shall be null and void 3 3 End User may obtain support for Software from Datalogic at Data logic s standard support fees and under Datalogic s...

Page 7: ...PROVIDED IN THIS AGREEMENT THE DATALOGIC PRODUCT IS PROVIDED AS IS AND DATALOGIC MAKES NO WAR RANTIES OF ANY KIND EXPRESS OR IMPLIED WRITTEN OR ORAL WITH RESPECT TO THE PRODUCT AND SPECIFICALLY DISCLA...

Page 8: ...eous agree ments written or oral between the parties concerning the licens ing of the Software This Agreement may not be changed amended or modified except by written document signed by Data logic 11...

Page 9: ...y the laws of the State of Hong Kong This Agreement and the rights of the parties hereunder shall be governed by and construed in accordance with the laws of the State of Hong Kong without regard to t...

Page 10: ...Software Product Policy viii PowerScan PM9500 NOTES...

Page 11: ...PM9500 DHPXX Autofocus optic high standard and low density codes Wide angle Display and 4 keys keypad Omni directional Operating To read a symbol or capture an image you sim ply aim the reader and pul...

Page 12: ...toscan command causes the reader to scan continuously and to monitor the central zone of its reading area Flash Memory Flash technology allows you to upgrade the PowerScan PM9500 reader as new symbolo...

Page 13: ...tery follow the instructions in this manual NOTE To charge the Battery Pack See Charging the Batteries on page 6 Datalogic recommends annual replacement of rechargeable battery packs to ensure maximu...

Page 14: ...your Datalogic reseller The use of any other power supplies can damage the device and void your warranty Do not disassemble or modify the battery The battery contains safety and protection devices wh...

Page 15: ...ng on usage and num ber of charges etc after which they should be removed from service especially in mission critical applications Do not continue to use a battery that is showing excessive loss of ca...

Page 16: ...n The battery can also be charged in the spare battery slot BC91xx models only or using the Multi Battery Charger accessory Changing the Batteries 1 Push the button at the bottom of the handle as show...

Page 17: ...o enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal operation Configur...

Page 18: ...ngs and labels refer to the PRG Set Date and Time 1 Scan the Enter Exit Programming bar code below to set date and time ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date bar code six digits for Year Mon...

Page 19: ...the handheld with the base To link the handheld and the base press the trigger to wake up the handheld and mount it on the base If the reader was previously linked to another base you must first scan...

Page 20: ...is pulled and released scanning is activated until programmable dura tion1 has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout1 pre vents undesired mult...

Page 21: ...Reference Guide 11 Operating Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Pulse Multiple Scan Mode Trigger Hold Multiple Scan Mode Flashing Scan Mode Always On...

Page 22: ...and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowl edged or transmitted to the host It is active only in Trigg...

Page 23: ...or descriptions of these features and programming labels Technical Specifications The following tables contain Physical and Performance Characteristics User Environment and Regulatory infor mation Pic...

Page 24: ...000 reads typical Cradle consump tionandDCinput supply range Volt 10 30 VDC Power 8Wb Max 500mA when in host bus powered modeb a ChargeTimes are much lower when battery is within daily typical operati...

Page 25: ...ased on EAN All other 1D codes are Code 39 All labels grade A 300 lux ambient light 20 C label inclination 10 Symbology Standard Model High Performance Code 39 4 mils 6 17 cm 20 mils 4 55 cm 40 mils 4...

Page 26: ...including Australian Post China Post Japanese Post KIX Post Planet Code Postnet Royal Mail Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Composites GS1 Databar Expanded Stack...

Page 27: ...ep can be disabled using programming bar code labels Contaminants Spray rain Dust particulates IP65 ESD Level 20 KV Beeper Speaker 80 dB 10 cm Regulatory See the Regulatory Addendum for details Radio...

Page 28: ...rmation The reader will beep once at current fre quency volume tonal setting and duration upon a success ful label scan Green Spota flashes momentarily Upon success ful read of a label the soft ware t...

Page 29: ...eps of descending frequency ROM Failure There is an error in the reader s software pro gramming Flashes Reader sounds one error beep at highest vol ume Limited Scan ning Label Read Indicates that a ho...

Page 30: ...Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A Read...

Page 31: ...eld Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes bee...

Page 32: ...during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol C...

Page 33: ...m the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects in wo...

Page 34: ...man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive events that would cause internal and external compo nent damage or destruction of th...

Page 35: ...eby assume any liability in connection with the return shipment Ergonomic Recommendations Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep obj...

Page 36: ...strial Handheld Scanners category link From this page you can select your product model from the drop down list which gives you access to Downloads including Data Sheets Manuals Software Utilities and...

Page 37: ...Hex Numeric Keypad Quick Reference Guide 27 Hex Numeric Keypad Use the barcodes that follow to enter numbers or alpha characters as you would select characters from a keypad 0 1 2 3 4...

Page 38: ...Hex Numeric Keypad 28 PowerScan PM9500 Hex Numeric Keypad continued 5 6 7 8 9...

Page 39: ...Hex Numeric Keypad Quick Reference Guide 29 Hex Numeric Keypad continued A B C D E F...

Page 40: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 U S A Telephone 541 68...

Reviews: