background image

NAFVJGS TS-30 programming manual

Summary of Contents for TS-30

Page 1: ...NAFVJGS TS 30 programming manual...

Page 2: ...n this manual are for reference only please refer to the actual product For the upgrade update and improvement of this product the company has the right without prior notice All information contained...

Page 3: ...x 11 8mm changed to 21 4mm x 12 38mm x 11 8mm 2 Steady time duration Default 400ms changed to 0ms 2 Added functions 1 Billing mode local billing online billing 2 Control character output function 3 GS...

Page 4: ...ting 15 Chapter 2 Flags 17 The third part of setting code configuration instructions 32 Chapter 1 Operational Settings 33 1 1 Use setting code 33 1 2 Restore factory default 34 1 3 User default settin...

Page 5: ...ty 46 3 4 5 Image stabilization duration 47 Chapter 4 Fill Lighting and Positioning 48 4 1 Fill light 48 4 2 Positioning 48 Chapter 5 Prompt Output 50 5 1 Buzzer main switch 50 5 2 Buzzer settings 50...

Page 6: ...rt full code open mode 69 Chapter 8 Symbology Settings 70 8 1 Global Shortcuts 70 8 1 1 Global Operations 70 8 1 2 Commodity barcode check digit output enable 71 8 1 3 Strengthening literacy ability 7...

Page 7: ...0 9 2 Cancellation 90 Chapter 10 Batch Setup 91 Addendum 92 Appendix A Data Code 92 0 to 92 A to F 93 Appendix B Parameter Setting Example 94 Appendix C Default Settings Table 98 Appendix D Common Ser...

Page 8: ...Product Description...

Page 9: ...n be flexibly applied to various equipment WSM QL1601 adopts advanced image recognition algorithm which can easily read all kinds of 1D barcodes and 2D barcodes WSM QL1601 has strong reading ability a...

Page 10: ...I Plessey RSS 14 Limited RSS Extended RSS read depth of field EAN 13 4 0 20 0cm 13mil Code128 4 5 25 0cm 15mil QR Code 4 0 18cm 15mil read angle Rotation 360 tilt 60 yaw 60 read precision one dimen si...

Page 11: ...shock resistance shock 5 200Hz 10Grms 3axes 1 5Hr fall Withstands a 1 2 meter drop to concrete heat resistant impact lowest temperature 20 C 4 F Highest temperature 60 C 140 F cycle frequency 30 minu...

Page 12: ...t is recommended to float externally PIN2 power supply VCC Input 3 3V PIN3 land GND PIN4 enter RX The module s TTL serial port receives PIN5 output TX The TTL serial port of the module sends PIN6 ente...

Page 13: ...SM QL1601 module are directly connected to the external circuit and the trigger pin and buzzer pin need a drive circuit please refer to the following circuit design Trigger pin TRIG drive circuit Pass...

Page 14: ...When decoding is successful BEEP and DLED pins will give a high level pulse Note The duration of the BEEP pulse is 60ms which can be set DLED pulse duration is 100ms...

Page 15: ...rk in high temperature environment in high temperature environment it will increase image noise reduce image quality and reduce reading performance Consider the actual use environment to determine whe...

Page 16: ...the window does not exceed 2mm The gap between the front of the module and the proximal end of the window is used to protect the module and window from external shocks when dropped If the window need...

Page 17: ...applications you can purchase DECODE_EVB to help users test and evaluate the module faster DECODE_EVB includes buzzer and drive circuit LED prompt and its drive circuit TTL 232 to RS 232 and interfac...

Page 18: ...Serial command configuration instructions...

Page 19: ...fault serial communication parameters of the reading module are as follows parameter Default parameter value baud rate 9600bps Check Digit no verification data bits 8 bits stop bit 1 person hardware f...

Page 20: ...x00 read successful Lens Indicates the number of bytes of uploaded Datas 0x00 means 256 Datas 0x00 0xFF indicating the read data CRC CRC_CCITT check value Calculation range The calculation method of T...

Page 21: ...en configuring multiple flag bits the data field must be filled in the order of addresses from low to high CRC CRC_CCITT check value 2 bytes Calculation range The calculation method of Types Lens Addr...

Page 22: ...individually it must keep the entire list at the same time Command format Input Head1 Types Lens Address Datas CRC Among them Head1 0x7E 0x00 Types 0x09 Lens 0x01 Address 0x0000 Datas 0x00 CRC CRC_CC...

Page 23: ...0 Datas 0xFF CRC CRC_CCITT check value Returns Head2 Types Lens Datas CRC 1 Set successfully Among them Head2 0x02 0x00 Types 0x00 write successful Lens 0x01 Datas 0x00 CRC CRC_CCITT check value 0x33...

Page 24: ...itioning light always on Bit3 2 00 fill light always off 01 fill light on when taking pictures 10 11 fill light always on Bit1 0 00 Manual mode 01 Command trigger mode 10 Continuous mode 11 Sensing mo...

Page 25: ...0x0007 data bits Features Bit7 Automatic deep sleep function 1 enabled 0 not enabled Bit6 0 Idle time high bit 14 8 Unit 100ms flag bit 0x0008 data bits Features Bit7 0 Idle time low bit 7 0 Unit 100...

Page 26: ...at 00 GBK 01 UNICODE 10 Original data 11 UTF8 Bit1 0 00 Serial output 01 USB HID 10 Serial HID simultaneous output 11 USB virtual serial port flag bit 0x000E data bits Features Bit7 4 Light sleep idle...

Page 27: ...ut reserved time unit 10ms 0x00 0xFF 0 2550ms flag bit 0x002B 0x002A data bits Features Bit15 reserve Bit14 13 Parity Mode 0 No parity 1 Odd parity 2 Even parity Bit12 0 0x09C4 serial port baud rate i...

Page 28: ...EAN13 code flag bit 0x002F data bits Features Bit7 1 reserve Bit0 Read EAN8 code 0 Forbid to read EAN8 code 1 Allow to read EAN8 code flag bit 0x0030 data bits Features Bit7 1 reserve Bit0 Read UPC A...

Page 29: ...g 0x00 0xFF 0 255Byte flag bit 0x0035 data bits Features Bit7 0 Code128 message maximum length setting 0x00 0xFF 0 255Byte flag bit 0x0036 data bits Features Bit7 1 reserve Bit0 Read Code39 code 0 For...

Page 30: ...F 0 255Byte flag bit 0x003C data bits Features Bit7 2 reserve Bit1 CodaBar code sending start and stop 0 Prohibit sending start stop characters 1 Allow sending start stop characters Bit0 Read CodaBar...

Page 31: ...minimum length setting 0x00 0xFF 0 255Byte flag bit 0x0042 data bits Features Bit7 0 Interleaved 2 of 5 message maximum length setting 0x00 0xFF 0 255Byte flag bit 0x0043 data bits Features Bit7 1 re...

Page 32: ...it 0x0048 data bits Features Bit7 0 Matrix 2 of 5 message maximum length setting 0x00 0xFF 0 255Byte flag bit 0x0049 data bits Features Bit7 1 reserve Bit0 Read Code11 code 0 Forbid to read Code11 cod...

Page 33: ...gth setting 0x00 0xFF 0 255Byte flag bit 0x004F data bits Features Bit7 1 reserve Bit0 Read RSS 14 code 0 Forbid to read RSS 14 code 1 Allow to read RSS 14 code flag bit 0x0050 data bits Features Bit7...

Page 34: ...PDF417 code 0 Forbid to read PDF417 code 1 Allow to read PDF417 code flag bit 0x0060 data bits Features Bit7 Whether the serial port virtual serial port output has a protocol 0 raw data 1 with protoco...

Page 35: ...aracter length 0x00 0x0F Suffix character length flag bit 0x0063 0x0071 data bits Features Bit7 0 prefix 0x00 0xFF prefix character value up to 15Byte flag bit 0x0072 0x0080 data bits Features Bit7 0...

Page 36: ...5 characters flag bit 0x00B2 data bits Features Bit7 0 Post truncated length N 0x00 0xFF 0 255 characters flag bit 0x00D9 write only flag data bits Features Bit7 0 function flag 0x50 Factory reset 0x5...

Page 37: ...64 V1 00 0x6E V1 10 0x78 V1 20 0x82 V1 30 0x8C V1 40 flag bit 0x00E2 read only flag data bits Features Bit7 0 Software version 0x64 V1 00 0x6E V1 10 0x78 V1 20 0x82 V1 30 0x8C V1 40 flag bit 0x00E3 re...

Page 38: ...re month the value represents the month 0x09 September 0x0A October 0x0B November flag bit 0x00E5 read only flag data bits Features Bit7 0 Software date this value represents the date 0x0A number 10 0...

Page 39: ...The third part of setting code configuration instructions...

Page 40: ...module setting code function can be performed After the function is turned on the parameters of the reading module can be modified by reading one or more setting codes After reading the close setting...

Page 41: ...function with caution 1 3 User Default Settings In addition to restoring factory settings users can save frequently used settings as user default settings By reading Save current settings as user def...

Page 42: ...code setting When users need to output USB and serial port at the same time they can select HID TTL simultaneous output mode by reading the setting code When the user switches the communication mode...

Page 43: ...n be connected to most application architectures but when the form of RS 232 must be used an external conversion circuit needs to be added The default serial communication parameters of the reading mo...

Page 44: ...are 3 possible verification methods as follows No check None Odd Parity Even Parity 2 3 USB HID interface related configuration 2 3 1 HID class device selection When a device is a HID class device it...

Page 45: ...PC access cycle to the HID device the cycle range 1ms 64ms 1ms 3ms 5ms 10ms 2 3 3 Time interval before HID release Read the following setting codes you can modify the time interval before HID release...

Page 46: ...e to the next valid message the interval range 1ms 63ms 1ms 2ms 5ms 10ms 2 3 5 CapsLock state setting CapsLock Off CapsLock On 2 3 6 HID leading key output Users can read the following setting codes s...

Page 47: ...ing time exceeds a single reading time the shooting and reading will be suspended Manual mode 3 1 1 Trigger Conditions In manual mode the trigger condition can be selected The default trigger conditio...

Page 48: ...the reading is unsuccessful after the reading is triggered When this time is exceeded the reading state will be exited The duration of a single reading code ranges from 100ms to 25500ms Read the follo...

Page 49: ...for manual mode and TTL 232 serial port mode output Light sleep idle time 0ms Light sleep idle time 500ms Light sleep idle time 3000ms Light sleep idle time 5000ms 3 2 Command trigger mode starts sho...

Page 50: ...continuously and cyclically performs shooting reading and outputting information In this mode the reading interval of 1000ms will be entered by default after the reading is successful In continuous m...

Page 51: ...delay reading the same barcode in this mode for a set period of time The same code reading delay means that after reading a bar code the same bar code is refused to be read within the set time It can...

Page 52: ...arts to read After the reading successfully outputs the information or the single code reading time expires the reading module needs a certain interval can be set to re enter the monitoring state If t...

Page 53: ...reading delay Please refer to Section 3 3 2 Recognize the same code reading delay setting code for setting the same code reading delay setting code 3 4 4 Sensitivity Sensitivity refers to the degree...

Page 54: ...odule that detects the scene change needs to wait for the image to stabilize before reading the code in the induction reading mode The setting range of image stabilization time is 0 25500 ms and the s...

Page 55: ...ght will continue to glow after the reading module is turned on Fill light always off the fill light does not light up under any circumstances Fill light lights up when taking pictures Fill light alwa...

Page 56: ...er the reading module is turned on positioning light is always off the positioning light does not light up under any circumstances Location light lights up when taking pictures Positioning light alway...

Page 57: ...the following setting codes to turn on off all beeps mute on mute off 5 2 Buzzer setting 5 2 1 Passive buzzer Read the following setting codes the buzzer can be set as passive and the driving frequen...

Page 58: ...nd active high level when working reading low level the buzzer is set to active high level when idle and low level when working level is valid Active buzzer High level low level 5 3 Set the code readi...

Page 59: ...ace by default and prompt through the external passive buzzer and LED These signals can be turned off according to user requirements Turn on the reading success prompt LED Turn off the reading success...

Page 60: ...oding format Note GBK format is used for Notepad UNICODE format is used for Word and common chat tool input boxes Original data output serial output for encrypted data Output Data Format GBK Output Da...

Page 61: ...Virtual Keyboard Enable In order to adapt to more regional application environments the output settings of the standard virtual keyboard can be performed by reading the following setting codes But it...

Page 62: ...put operation of the control function keys is as follows Please refer to the control character correspondence table for the corresponding relationship between the specific ASCII values and the control...

Page 63: ...the virtual keyboard operation of the scanning module is as follows Type Alt 0 9 the virtual keyboard will hold Alt then press 0 and 9 on the numeric keypad and finally release Alt When the standard...

Page 64: ...K hyperlink FF 0C Delete Ctrl L list left align CR 0D Enter Ctrl M SO 0E Insert Ctrl N New SI 0F Esc Ctrl O Open DLE 10 F11 Ctrl P Print DC1 11 Home Ctrl Q Quit DC2 12 PrintScreen Ctrl R DC3 13 Backs...

Page 65: ...des Inverting Disable Inverting Enable 5 11 Billing Mode In order to facilitate the use of this module in the invoicing system the user can configure the invoicing mode by reading the setting code and...

Page 66: ...rite Read Device ID The user can read and write the ID through the serial port or virtual serial port and the ID can be up to 16 Bytes pure numbers and uppercase and lowercase letters Write ID format...

Page 67: ...he ID is not written read the device ID and return DeviceID NULL 3 If the write command ID data does not meet the requirements or the command format is wrong the write command will be sent without ret...

Page 68: ...e ID Decoding failure characteristic output information RF information Add a terminator Tail Processed output data format Prefix Code ID Data Suffix Tail 6 1 Prefix The prefix is a string of strings d...

Page 69: ...Suffixes are allowed Suffixes are not allowed Read the following setting codes and cooperate with the Data Code setting code and the Save setting code the user can modify the suffix content modify su...

Page 70: ...can be found in Appendix E Restore Code ID default value 6 3 2 Modify Code ID Users can modify the Code ID corresponding to each barcode by reading the following setting codes Modify the Code ID of EA...

Page 71: ...y the Code ID of Codabar Modify the Code ID of Interleaved 2 of 5 Modify the Code ID of Industrial 25 Modify the Code ID of Matrix 2 of 5 Modify the Code ID of Code11 Modify the Code ID of MSI Plessey...

Page 72: ...dd CR terminator 0x0D Add TAB terminator 0x09 Add CRLF terminator 0x0D 0x0A 6 5 Data segment 6 5 1 Date segment interception This function is used in scenarios where the user needs to output partial d...

Page 73: ...er Refer to Appendix F for the hexadecimal conversion table corresponding to characters Modify the length of the Start segment and modify the length of the End segment 6 6 RF Information Read Fail RF...

Page 74: ...ading the following setting codes The format of the decoding result with protocol output is 03 length decoded data Pure data output with protocol output 6 8 GS Character Substitution GS as a group sep...

Page 75: ...ode GS character replacement enable GS character replacement disable Read the following setting codes and cooperate with the Data Code setting code and the Save setting code the user can modify the GS...

Page 76: ...s can quickly configure the reading device to work in POS mode by reading the following setting codes Fast POS Mode 7 2 Serial port full code open mode In order to facilitate customers to quickly conf...

Page 77: ...ions By reading the following setting codes users can globally enable disable reading and enable the default reading type for all supported symbologies After all types of code systems are prohibited f...

Page 78: ...ity The barcode reading ability enhancement can be enabled and disabled by reading the following setting codes After reading ability enhancement is enabled the ability to read special codes such as de...

Page 79: ...EAN13 does not require additional code output By reading the following setting codes users can configure the enabling and disabling of EAN13 additional codes EAN13 2 digit additional code enable EAN1...

Page 80: ...codes EAN8 forces the output of additional codes EAN8 does not require additional codes to be output By reading the following setting codes the user can configure the enabling and disabling of the EAN...

Page 81: ...tion of the UPC A additional code by reading the following setting codes UPC A mandatory output of additional code UPC A does not require output of additional code Users can configure the enabling and...

Page 82: ...and disable the UPC E0 barcode reading function by reading the following setting codes Allow UPC E0 to read and disable UPC E0 to read 2 Additional code forced output function enable and disable The u...

Page 83: ...5 digit additional code disable 8 2 5 UPC E1 1 Permission and prohibition of reading function Users can enable and disable the UPC E1 barcode reading function by reading the following setting codes A...

Page 84: ...odes UPC E1 2 digit additional code enable UPC E1 2 digit additional code disable UPC E1 5 digit additional code enable UPC E1 5 digit additional code disable 8 2 6 Code128 1 Permission and prohibitio...

Page 85: ...2 The longest length of Code128 message is 255 8 2 7 Code39 1 Permission and prohibition of reading function Code39 barcode reading function by reading the following setting codes Allow Code39 reading...

Page 86: ...t character and end character by reading the following setting codes Code39 starter output Code39 starter not output Code39 terminator output Code39 terminator not output 4 Code32 mode Users can set w...

Page 87: ...mode not supported 8 2 8 Code93 1 Permission and prohibition of reading function Users can enable and disable the Code93 barcode reading function by reading the following setting codes Allow Code93 re...

Page 88: ...mission and prohibition of reading function CodaBar barcode reading function by reading the following setting codes Allow CodaBar to read prohibit CodaBar to read 2 Read length setting Users can set t...

Page 89: ...t stop character output CodaBar start stop character does not output 8 2 10 Interleaved 2 of 5 1 Permission and prohibition of reading function Interleaved 2 of 5 barcode reading function by reading t...

Page 90: ...ges have a maximum length of 255 8 2 11 Industrial 25 1 Permission and prohibition of reading function Industrial 25 barcode reading function by reading the following setting codes Allow Industrial 25...

Page 91: ...on of reading function Matrix 2 of 5 barcode reading function by reading the following setting codes Allow Matrix 2 of 5 to read Matrix 2 of 5 reading is prohibited 2 Read length setting Users can set...

Page 92: ...format is Mod 10 Matrix 2 of 5 check format is None 8 2 13 Code11 1 Permission and prohibition of reading function Code11 barcode reading function by reading the following setting codes Allow Code11 t...

Page 93: ...odes Code11 1bit verification Code11 2bit verification 8 2 14 MSI Plessey 1 Permission and prohibition of reading function Allow MSI Plessey to read Disable MSI Plessey reading 2 Read length setting t...

Page 94: ...eading function by reading the following setting codes Allow RSS 14 reading Disable RSS 14 reading 8 2 16 Qualified RSS The permission and prohibition of the reading function limited RSS barcode readi...

Page 95: ...tting Extended RSS messages have a minimum length of 0 Extended RSS messages have a minimum length of 4 The maximum length of extended RSS information is 32 and the maximum length of extended RSS info...

Page 96: ...ble the simultaneous reading of multiple DM codes by reading the following setting codes Allows multiple DM functions to be read at the same time Prohibit reading multiple DM functions at the same tim...

Page 97: ...ed to read the Save setting code to save the data save 9 2 Cancellation When there is an error in reading the data the following setting codes can be read to cancel the current setting cancel the one...

Page 98: ...The user can save all the information to be set as a QR code and the device can complete multiple settings after reading the QR code The following are guidelines for batch setup 1 Batch setting code c...

Page 99: ...3000ms command parameter 0202001E disable Read the command code of Interleaved 2 of 5 code command parameter 070A0100 the content of the batch setting code is as follows WSM00000000 02000003 03000000...

Page 100: ...twenty three 4 5 6 7 8 9 A to F...

Page 101: ...the character table to obtain the hexadecimal values corresponding to the four characters of DATA 44 41 54 41 2 Read the Enable setting code if it has been enabled you can skip this step 3 Read the m...

Page 102: ...table to obtain the hexadecimal value corresponding to the A character 41 2 Read the Enable setting code if it has been enabled you can skip this step 3 Read the Modify CODE ID of EAN13 setting code...

Page 103: ...nd A in sequence 5 Read the Save setting code 6 Read the setting code of Transmit only End segment Example 6 Only transmit Center segment When the decoding information is 1234567890ABC1234567890 outpu...

Page 104: ...9 4 C in sequence 5 Read the Save setting code Example 8 Modify the GS replacement character to D 1 Query the character table to get the hexadecimal value corresponding to the D character 44 2 Read t...

Page 105: ...e flow control none USB HID USB HID device selection USB KBW PC to HID device access cycle 1ms Range 1 64ms Interval before HID release 1ms Range 1 63ms Interval after HID release 1ms Range 1 63ms Cap...

Page 106: ...o delay Delay time range 100ms 25500ms Step 100ms 0x00 infinite delay Single reading time 5000ms Range 100ms 25500ms Step 100ms 0x00 infinite length Induction mode Single reading time 5000ms Range 100...

Page 107: ...rn on Read success tone turn on Reading success tone duration 60ms Range 0 255ms Reading success LED prompt turn on Set the code reading prompt tone turn on output data format GBK keyboard U S virtual...

Page 108: ...rification output Enable EAN13 EAN8 UPC A UPC E0 UPC E1 Strengthening reading ability prohibit EAN 13 read allow Force output of additional code Does not require 2 digit additional code prohibit 5 dig...

Page 109: ...de Does not require 2 digit additional code prohibit 5 digit additional code prohibit Code128 read allow message minimum length 4 message length 32 Code 39 read allow message minimum length 4 message...

Page 110: ...4 message length 32 Industrial 25 read prohibit message minimum length 4 message length 32 Matrix 2 of 5 read prohibit message minimum length 4 message length 32 Check format None Code11 read prohibi...

Page 111: ...D Common Serial Port Commands Features Serial command return command Set the baud rate to 9600 7E 00 08 02 00 2A 39 01 A7 EA 02 00 00 01 00 33 31 Save settings to internal Flash 7E 00 09 01 00 00 00...

Page 112: ...e corresponding character flag address EAN 13 d 0x91 EAN 8 d 0x92 UPC A c 0x93 UPC E0 c 0x94 UPC E1 c 0x95 Code 128 j 0x96 Code 39 b 0x97 Code 93 i 0x98 Codabar a 0x99 Interleaved 2 of 5 e 0x9A Indust...

Page 113: ...rix u 0xA3 PDF 417 r 0xA4 Appendix F ASCII Code Table hex decimal character 00 0 NUL Null char 01 1 SOH Start of Header 02 2 STX Start of Text 03 3 ETX End of Text 04 4 EOT End of Transmission 05 5 EN...

Page 114: ...gment 16 twenty two SYN Synchronous Idle 17 twenty three ETB End of Trans Block 18 twenty four CAN Cancel 19 25 EM End of Medium 1a 26 SUB Substitute 1b 27 ESC Escape 1c 28 FS File Separator 1d 29 GS...

Page 115: ...43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 E...

Page 116: ...47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Sl...

Page 117: ...core 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t...

Page 118: ...mand parameter content Remark Enable setting code 00000000 If the setting code is turned off you need to open the setting code first TTL 232 serial port mode 01000000 USB HID mode 01000001 USB 232 vir...

Page 119: ...rval before HID release 2ms 01050002 Time interval before HID release 5ms 01050005 Time interval before HID release 10ms 0105000A Time interval after HID release 1ms 01060001 The last two digits of th...

Page 120: ...nable the same code reading delay The same code reading delay is turned on 02060001 The same reading delay time unlimited delay 02070000 The same code reading delay time 500ms 02070005 The last two di...

Page 121: ...on 02030000 deep sleep function off 02030001 Light sleep idle time 0ms 02040000 The last two digits of the parameter can be modified for other durations Light sleep idle time 500ms 02040001 Light sle...

Page 122: ...04013C Reading success prompt tone duration 90ms 0404015A The duration of the sound of successful reading is 120ms 04040178 Output data format GBK 04050000 Output data format UTF8 04050001 Output data...

Page 123: ...5000000 Prefix not allowed 05000001 modify prefix 05000002 suffix is allowed 05010000 No suffixes are allowed 05010001 modify suffix 05010002 Allow adding CODEID 05020000 Forbid adding CODEID 05020001...

Page 124: ...ify the CODEID of the DataMatrix 05030013 Modify the CODEID of the limited PDF417 05030014 close terminator 05040000 Add terminator CR 05040001 Add the terminator TAB 05040002 Add terminator CRLF 0504...

Page 125: ...ow to send product code check digit 05090000 It is forbidden to send the check digit of the product code 05090001 Allow reading EAN13 07010000 Prohibit reading EAN13 07010100 EAN13 forced output addit...

Page 126: ...l code disable 07032100 UPCA 5 digit additional code enable 07033000 UPCA 5 digit additional code disable 07033100 Allow UPCA to EAN13 05080000 Ban UPCA to EAN13 05080001 Allow reading UPC E0 07040000...

Page 127: ...rmation is 32 07061120 The maximum length of Code128 information is 255 070611FF Allow reading Code39 07070000 Prohibit reading Code39 07070100 The shortest length of Code39 information is 0 07071000...

Page 128: ...0 07091000 Other lengths can be modified the last two digits of the parameter The minimum length of CodaBar information is 4 07091004 The maximum length of CodaBar information is 32 07091120 The maxi...

Page 129: ...mation is 0 070C1000 Other lengths can be modified the last two digits of the parameter Matrix 2 of 5 message has a minimum length of 4 070C1004 The maximum length of Matrix 2 of 5 information is 32 0...

Page 130: ...ohibit reading limited RSS 070F1100 Allows to read extended RSS 070F2000 Prohibit reading of extended RSS 070F2100 The minimum length of RSS information is 0 070F3000 Other lengths can be modified the...

Page 131: ...Cancel a string of data previously read 08000002 Cancel modify settings 08000003 0 08010000 1 08010001 2 08010002 3 08010003 4 08010004 5 08010005 6 08010006 7 08010007 8 08010008 9 08010009 A 080100...

Reviews: