Page 1: ...GV Card Reader Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use User s Manual READER D ...

Page 2: ...tal or consequential damages arising from the use of the information or products contained herein Features and specifications are subject to change without notice GeoVision Inc 9F No 246 Sec 1 Neihu Rd Neihu District Taipei Taiwan Tel 886 2 8797 8377 Fax 886 2 8797 8335 http www geovision com tw Trademarks used in this manual GeoVision the GeoVision logo and GV series products are trademarks of Ge...

Page 3: ...with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measur...

Page 4: ...ii Preface Welcome to the GV Card Reader User s Manual This Manual applies to the following GV Card Readers Reader Models GV Reader1251 and 1352 V2 GV SR1251 GV RK1352 R1352 GV DFR1352 Rev B GV RKD1352 ...

Page 5: ... AS Controller through RS 485 Interface 6 1 3 3 Connecting to GV DVR NVR and Third Party Access Controllers 8 1 4 Overlaying Card Numbers on GV DVR NVR Live View 9 1 5 Changing the Default Settings of Beeper and LED 10 1 6 Specifications 11 Chapter 2 GV RK1352 R1352 DFR1352 12 2 1 Packing List 13 2 2 Physical Descriptions 14 2 2 1 Electric Wire 14 2 2 2 Keypad GV RK1352 Only 16 2 2 3 LED Indicator...

Page 6: ...nd LED on GV R RK DFR Config AP 25 2 6 2 Wiring the Beeper and LED to GV AS Controller 27 2 6 3 Configuring the Beeper and LED Settings for Each Door Gate 28 2 7 Setting UID or GID on GV R RK DFR Config AP 29 2 8 Firmware Upgrade 31 2 9 Specifications 32 2 10 Accessory GV RK1352 and GV R1352 Only 33 Chapter 3 GV RKD1352 34 3 1 Packing List 34 3 2 Compatible Products 34 3 3 Physical Descriptions 35...

Page 7: ...indicator is controllable by the host system and changes from red to green to indicate access granted GV Reader1251 1352 V2 SR1251 also has a host controllable buzzer 1 1 Packing List If any of the items are missing or damaged contact your dealer to arrange a replacement For GV Reader 121 1352 V2 1 GV Reader1251 1352 V2 2 Bag of screws 3 GV Reader Software CD 4 Warranty Card For GV SR1251 1 GV SR1...

Page 8: ...ntrol is the internal control When the setting is On the Reader is sounded after a card is read When the setting is Off the Beeper is controlled externally You can use the external beeper control line to activate the beeper Wire Color Function Red DC 7 5 12 V Black GND Green Wiegand Data 0 White Wiegand Data 1 Blue RS 485 Light Blue RS 485 Yellow Beeper Orange Green LED Light Red Red LED ...

Page 9: ...der is controlled by Wiegand signal When the setting is Off the Reader is for RS 485 signal SW5 SW7 ID Setting Switch 5 to switch 7 is used to set the Reader s ID for wiring in a daisy chain ID 0 1 2 3 4 5 6 7 SW5 OFF OFF OFF OFF ON ON ON ON SW6 OFF OFF ON ON OFF OFF ON ON SW7 OFF ON OFF ON OFF ON OFF ON SW8 RS 485 Terminal Resistor When the setting is On a 120 ohm resistor is connected between RS...

Page 10: ...FR Config AP 3 Select the COM port that is connected to the reader and click Open COM The red square next to the COM port box should change to blue to indicate the COM port is correct 4 Select an ID number for the reader The ID number ranges from 0 to 7 5 Click Setup The serial number and firmware version of the reader will be automatically detected The settings are sent to the reader Note 1 To de...

Page 11: ...roller ensure the related switch setting on the GV Reader1251 1352 V2 is configured correctly Note Each reader consumes 60 mA of power The total power consumption of the output devices and readers connected to GV AS Controller must be under 2 5A for GV CS1320 3A for GV AS1620 GV AS210 2110 2120 3 5A for GV AS410 4110 or 5A for GV AS810 8110 Connect an external power supply if the power supplied fr...

Page 12: ...to GV AS Controller through a single RS 485 cable When you connect more than one GV Reader to GV AS Controller on the last connected GV Reader turn SW8 to ON Make sure to define the ID of each reader with SW5 to SW7 first GV Reader 1 GV Reader 8 1 2 3 4 5 6 7 8 ON ECE 1 2 3 4 5 6 7 8 ON ECE ID Number Setting for Connecting Multiple GV Readers RS 485 GV SR1251 only Multiple readers can be connected...

Page 13: ...GV AS Controller 1 Type the GV AS Controller s IP address in the Web browser 2 Type the username and password to login 3 In the left menu click Extended Reader This page appears 4 If the readers are connected using RS 485 select the RS485 checkbox in front of the ID number The ID number must match the ID you configured using SW5 SW7 for GV Reader1251 1352 V2 or GV R RK DFR Config AP for GV SR1251 ...

Page 14: ...to the access controller through the Wiegand interface connect the reader to GV DVR NVR via GV COM GV Hub or GV NET IO Card V3 1 Note The GV Reader1251 1352 V2 SR1251 is not compatible with the GV NET Card and the GV NET IO Card of versions earlier than V3 Light blue GV System GV COM GV Hub GV NET IO Card V3 1 Access Controller third party power supply 7 5 12 V Red Black Blue USB Green White GV Re...

Page 15: ... details see 2 5 Overlaying Card Numbers on GV DVR NVR Live View GV HUB GV COM GV NET IO Card GV DVR NVR Light Blue RS 485 Blue RS 485 USB GV Reader1251 1352 V2 SR1251 Note 1 For GV Reader1251 1352 V2 make sure to define the ID number and set the reader to slave by configuring the switch settings For details see 1 2 2 Switch Setting of GV Reader1251 1352 V2 2 For GV SR1251 make sure to define the ...

Page 16: ...ee 2 6 1 Setting up Beeper and LED on GV R RK DFR Config AP 2 For GV Reader1251 1352 V2 enable external control of the reader s Beeper and LED by configuring the switch settings For details see 1 2 2 Switch Setting 3 Wire the Beeper Red LED and Green LED from the reader to GV AS Controller For details see 2 6 2 Wiring the Beeper and LED to GV AS Controller 4 Specify the Beeper and LED settings for...

Page 17: ... Green Blue LED Red Green LED Beeper Buzzer Frequency 125 KHz Proximity EM Card 13 56 MHz for ISO14443A Mifare Class RS 485 9 600 bps distance 600 m 1968 50 ft Color Gray Operating Temperature 35 C 65 C 31 F 149 F Operating Humidity 10 90 RH non condensing Dimensions W x H x D 75 W x 115 H x 15 T mm with enclosure 35 T mm 3 W x 4 5 H x 0 6 T in with enclosure 1 38 T in Weight 150 g 0 33 lb 125 g 0...

Page 18: ... RK1352 comes with keypad allowing it to also recognize PIN codes GV DFR1352 is designed to be installed on the door frame Featured with the Wiegand and RS 485 outputs the readers can be connected to any standard access control panel The readers are protected by a weather sealed and IP66 compliant housing for outdoor use ...

Page 19: ...te x 1 5 Software CD 6 Installation Guide 7 Warranty Card GV R1352 1 GV R1352 Card Reader 2 Screw x 3 3 Screw Anchor x 2 4 Security Torx 5 Software CD 6 Installation Guide 7 Warranty Card GV DFR1352 1 GV DFR1352 Card Reader 2 Screw x 2 3 Screw Anchor x 2 4 Front Cover Plate x 2 5 Software CD 6 Installation Guide 7 Warranty Card ...

Page 20: ...e Green LED Light Red Red LED Green Wiegand Data 0 White Wiegand Data 1 Blue RS 485 Light Blue RS 485 Rear View GV R1352 Wire Color Function Red DC 7 5 12V Black GND Yellow Beeper Orange Green LED Light Red Red LED Green Wiegand Data 0 White Wiegand Data 1 Blue RS 485 Light Blue RS 485 Gray N A Purple N A Brown N A Rear View ...

Page 21: ...een Wiegand Data 0 White Wiegand Data 1 Blue RS 485 Light Blue RS 485 Gray N A Purple N A Brown N A Rear View Install the GV DFR1352 to the door frame using the supplied screws and screw anchors Before placing and sticking the front cover plate to the GV DFR1352 remove the Plastic Cover to prevent scratches to the cover after installed ...

Page 22: ...e card for access granted 2 2 3 LED Indicator and Beeper In standby mode the LED is blue When a card is read the LED flashes green and the beeper beeps once The reader comes with external control wires for Green LED Red LED and Beeper You can connect these control wires to GV AS Controller to change the default settings of the LED and Beeper For details on how to configure the settings see 2 6 Cha...

Page 23: ...110 Wiegand and RS 485 GV AS1620 Wiegand and RS 485 GV CS1320 RS 485 2 Each GV RK1352 R1352 DFR1352 consumes 60 mA of power The total power consumption of the output devices and readers connected to GV AS Controller must be under 2 5A for GV CS1320 3A for GV AS1620 GV AS210 2110 2120 3 5A for GV AS410 4110 or 5A for GV AS810 8110 Connect an external power supply if the power supplied from GV AS Co...

Page 24: ...DC 7 5 12V RS485 12V A A B B GND Reader 1 Black Light Blue Blue Red Reader 4 GV AS810 Controller GV RK1352 or GV R1352 Connecting five or more readers to GV AS810 Controller For readers five to eight connect the RS 485 cable to the RS 485 interface on GV AS810 Controller and then connect the 12V power output and GND of the reader to a 12V DC power output on the controller Red Black RS485 12V A A B...

Page 25: ...b interface you can also set the reader to read the GID or UID on GV AS ID Cards Key Fobs Note that the Web interface of different GV AS Controller models varies 1 On the controller s Web interface click Extended Reader This dialog box appears 2 In the GV Reader CR420 GF1921 GF1922 section select the RS485 checkbox in front of the ID number and type the Serial Number on the rear panel of the reade...

Page 26: ...one number on your GV AS ID Cards Key Fobs GID is not supported and you must select Unique Identification UID 5 Click Submit Note 1 When you click Submit on the Extended Reader page of GV AS1010 210 2110 2120 410 4110 810 8110 GV AS1620 GV CS1320 all readers connected through RS 485 interface will reboot 2 GID ID format is only supported in GV RK1352 GV R1352 GV DFR1352 Rev B V1 2 or later 3 If yo...

Page 27: ... 232 PC Light Blue RS 485 Blue RS 485 USB GV RK1352 You can install the Config AP from the GeoVision website To use a GV COM GV Hub or GV NET IO Card V3 1 you also need to install GV USB Device Driver to enable the device Downloading from GeoVision Website 1 Go to the download page of GeoVision Website https www geovision com tw download product GV RK1352 2 Download GV RK1352 GV R1352 GV DFR1352 C...

Page 28: ...NET IO Card RS 232 GV System Light Blue RS 485 Blue RS 485 USB GV RK1352 or GV R1352 Note GV RK1352 R1352 DFR1352 is not compatible with GV NET Card and GV NET IO Card of versions earlier than V3 2 5 1 Defining the ID Number and Setting the Reader to Slave After the reader is connected to the computer of the GV DVR NVR use the GV R RK DFR Config AP to define the ID number of the reader and set the...

Page 29: ...le readers to the GV DVR NVR you need to set up a unique ID number for each reader For this you need to connect each reader to the computer one reader at a time and follow the instructions above to set up an ID number Note 1 If the COM port is incorrect an Error opening serial port message will appear To verify the COM port that is connected to the reader go to Windows Device Manager In the Ports ...

Page 30: ...rs 2 Click the New button This dialog box appears Type Select GV Wiegand Capture Device Type a number and name to help you identify the reader COM Select the COM port connected to the reader Address Select the ID of the connected reader you set in GV R RK DFR Config AP Camera Assign the reader to a channel to overlay card numbers on the live view 3 Click the Add button ...

Page 31: ...Beeper and LED settings for each door through the Web interface of GV AS Controller Note GV AS1620 can also externally control the reader s LED and Beeper for access granted and denied For details see GV AS1620 User s Manual 2 6 1 Setting up Beeper and LED on GV R RK DFR Config AP To enable the external controls of the Beeper and LED on GV R RK DFR Config AP the reader needs to be connected to a c...

Page 32: ...Controller Web interface 6 Click Setup The settings are sent to the reader The serial number and the firmware version of the reader will be automatically detected If you want to set up multiple readers to be controlled by the controller you need to connect each reader to the computer one reader at a time and follow the above instructions to enable external control After the above settings you need...

Page 33: ... and GV AS810 as an example For Red LED use the light red wire instead Wire Color Function Black GND Orange Green LED Light Red Red LED GV AS810 Controller GV RK1352 or GV R1352 OUT11 OUT12 NC COM NO NC COM NO Green LED Orange 12V D0 D1 GND Black Green White Red Wiring Beeper to GV AS Controller The diagram below shows the connection for wiring the beeper using GV RK1352 and GV AS810 as an example...

Page 34: ...cify the conditions to trigger the beeper and LED on the GV AS210 2110 2120 410 4110 810 8110 Web interface 1 On the controller Web interface click Output Setting The page below appears 2 Find the output wired to the beeper or LED and specify up to 2 alarm conditions to set off the beeper or LED a Output Type Select Normal Toggle or Pulse If you select Pulse you can specify the number of seconds t...

Page 35: ...OM port of the reader see 2 4 Installing GV R RK DFR Config AP and 2 5 1 Defining the ID Number and Setting the Reader to Slave GID ID format is only supported in GV RK1352 GV R1352 GV DFR1352 Rev B V1 2 or later If you are using third party cards or key fobs you must set the reader to read UID 1 Run GV R RK DFR Config AP 2 Select the COM port that is connected to the reader and click Open COM The...

Page 36: ... version of the reader will be automatically detected To use GID make sure there are two numbers on your GV AS ID Cards Key Fobs as shown below If there is only one number on your GV AS ID Cards Key Fobs GID is not supported and you must select Unique Identification UID ...

Page 37: ...ruption of power supply during updating causes not only update failures but also damages to the device In this case please contact your sales representative and send your device back to GeoVision for repair To upgrade firmware 1 Insert the Software CD and select Run Firmware Update Utility This dialog box appears 2 Select the COM port of the reader 3 Click the Browse button to locate the firmware ...

Page 38: ...uzzer Reader Color Black Supported ID Formats GID and UID Operating Temperature 35 C 66 C 31 F 150 8 F Operating Humidity 10 90 no condensation Dimensions W x H x D 95 x 108 x 23 mm 3 74 x 4 25 x 0 91 in 65 8 x 115 6 x 20 5 mm 4 6 x 2 6 x 0 8 in 20 9 x 105 6 x 20 5 mm 0 8 x 4 2 x 0 8 in Weight 260 g 0 57 lb 120 g 0 26 lb 80 g 0 17 lb Ingress Protection IP66 Certification CE FCC RoHS UL 294 CUL For...

Page 39: ...A900 GV MountA900 is a mounting plate that allows you to attach GV RK1352 and GV R1352 to a US single gang power box Dimensions 100 x 68 mm 3 9 x 2 7 in Weight 55 g 0 12 lb Connecting GV MountA900 1 Screw GV MountA900 to the US single gang power box through holes C 2 Thread the cable through GV MountA900 and then attach the reader GV R1352 Secure through holes A GV RK1352 Secure through holes B C ...

Page 40: ...n be connected to any standard access control systems GV RKD1352 comes with IP65 rated ingress protection suitable for indoor and outdoor applications 3 1 Packing List 3 2 Compatible Products GV ASManager V5 3 3 or later GV AS210 2110 2120 GV AS810 8110 8111 GV AS410 4110 4111 V2 41 or later only Weigand interface supported GV AS1620 V1 05 or later GV CS1320 V3 10 or later ...

Page 41: ...GV RKD1352 35 3 3 3 Physical Descriptions A To define the reader s ID for a daisy chain connection set up the switches as listed below ...

Page 42: ...y the change B Connect the reader to GV AS Controller based on the following pin definitions Pin Wire Color Wiegand RS 485 1 Red DC 12V DC 12V 2 Black Ground Ground 3 Yellow RS 485 4 Blue RS 485 5 Gray Reserved 6 Pink 7 Orange White Ground 8 Orange 9 Brown Green LED Control 10 Purple Beep Control 11 White Case Sensor To Controller GND 12 Green Case Sensor To Controller Temper Sensor 13 Red White W...

Page 43: ...the controller 2 In order to reduce long distance noise the isolated net of transmission cable should connect to both ends of device ground 3 The distance between two readers should be over 30 cm to prevent radio frequency interference from each other 4 Mounting the reader around metal could affect read range Metal of any type around the reader should be avoided while mounting 5 The distance betwe...

Page 44: ...d then present the card for access granted 3 6 LED Status and Beeper By default the reader has the following LED status and beeper actions Condition Wiegand RS 485 Standby Constant Red No light Access Denied Beep once No LED Flash Red momentarily Beep three times Access Granted Beep once No LED Flash Green momentarily Beep twice For Wiegand connection the reader comes with external control wires f...