The nozzle will pause at the X corner, then return to the center, and move to the Y tower
and pause. After the pause, it will again move to the center, and move to the Z tower, pause,
and return to the center.
Your focus should be is on the nozzle when it pauses. You want to compare the gap at
the tower to the gap at the center.
– If the nozzle at the tower RAISES (compared to the CENTER), you want to adjust the screw
that hits the end-stop by turning it counterclockwise (moving the screw up).
– If the nozzle at the tower LOWERS (compared to the CENTER), you want to adjust the screw
that hits the end-stop by turning it clockwise (moving the screw down).
Pic of screw you will adjust:
*** Make small changes to the screw about 1/8 – ¼ turn adjustments***
11) After you have adjusted the screws, You have changed the Z height, so you want to go back
and re-set the Z height the way you did earlier in this guide.
30