Setting
value
Function
Description
14
Torque limited
In the speed control mode of the frequency converter, when the
output torque reaches the torque limit value, the frequency
converter is in the stall protection state and outputs an ON signal
at the same time.
15
Ready for run
When the power supply of the main circuit and the control circuit of
the inverter has stabilized, and the inverter has not detected any
fault information, and the inverter is in a operable state, it outputs
an ON signal.
16
AVI1>AVI2/ACI
When the value of analog input AVI1 is greater than the input value
of AVI2/ACI, an ON signal is output.
17
Upper limit frequency reached
When the running frequency reaches the upper limit frequency, the
ON signal is output.
18
Lower limit frequency reached
(operation valid)
When the running frequency reaches the lower limit frequency, the
ON signal is output. The output is OFF in the stop state.
19
Undervoltage state output
When the inverter is undervoltage state, it outputs ON signal.
20
Communication setting
Please refer to the communication protocol.
21
Reserved
Reserved
22
Reserved
Reserved
23
Zero speed running 2 (also
output when stopped)
When the output frequency of the inverter is 0, the ON signal is
output. This signal is also ON in the stop state.
24
Cumulative power-on time
arrival
When the cumulative power-on time (08-13) of the inverter
exceeds the set time of 09-16, it outputs an ON signal.
25
Frequency level detection FDT2
output
Please refer to the parameters 09-28,09-29
26
Frequency 1 reaches the output Please refer to the parameters 09-30,09-31
27
Frequency 2 reaches the output Please refer to the parameters 09-32,09-33
28
Current 1 reaches the output
Please refer to the parameters 09-38,09-39
29
Current 2 reaches the output
Please refer to the parameters 09-40,09-41
30
Timing reached
When the timing function selection (09-42) is valid, the inverter will
output an ON signal after the current running time of the inverter
reaches the set time.
31
AVI1 input exceeds limit
When the value of analog input AVI1 is greater than 09-46 (AVI1
input protection upper limit) or less than 09-45 (AVI1 input
protection lower limit), ON signal is output.
32
Lost load
When the inverter is in the load drop state, it outputs ON signal.
33
Reverse running
When the inverter is running in reverse, output ON signal
34
Zero current state
Please refer to the parameters 09-34,09-35
35
Module temperature reached
Inverter module radiator temperature (08-08) reaches the set
module temperature reached value(09-47), output ON signal
36
Software current limit exceeded
Please refer to the parameters 09-36,09-37
37
Lower limit frequency reached
(also output when stopped)
When the running frequency reaches the lower limit frequency, the
ON signal is output. The signal is also ON in the stop state.
38
Warning output
When the inverter fails, and the fault handling mode is Continue to
run, the inverter warning output.
Summary of Contents for S3100E Series
Page 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Page 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...