![Savch S3100E Series User Manual Download Page 34](http://html.mh-extra.com/html/savch/s3100e-series/s3100e-series_user-manual_1203759034.webp)
30
3.2.6 Quick Debugging
Start
01- 00=0?
Correctly set
group 01 of motor
parameters
Select the suitable accel and
decel time (set 00-07,00-08)
Motor parameters
self-taught
(set 01-01)
Select running
command channel
(set 00-00)
Select the suitable
frequency command
(set 00-01,00-02 , etc)
Select the start-stop
mode of motor
(set 07-01)
Select the suitable
accel and decel time
(set 00-07,00-08)
Select the start-stop
mode of motor
(set 07-05)
Start motor and observe,
refer to the fault solutions
if faults received
Reach the
required control
End
Yes
No
No
Yes
Select control
mode(set 01-00)
Summary of Contents for S3100E Series
Page 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Page 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...