Instantaneous power failure action pause judgment
voltage
Factory setting
85%
Setting range 80
~
100%
11-61
Judgment time of instantaneous power failure voltage rise
Factory setting
0.5s
Setting range 0.0s
~
100.0s
11-62
Judgment voltage of instantaneous power failure
Factory setting
80%
Setting range 60%
~
100%(Standard bus Voltage)
Refers to the moment when there is a power failure or the voltage drops suddenly, the inverter reduces the output
speed, so that the load feedback energy maintains the inverter DC bus voltage, so that the inverter continues to
run.
If 11-59=1, the inverter decelerates when there is an instantaneous power failure or a sudden drop in voltage, and
when the bus voltage returns to normal, the inverter normally accelerates to the set frequency. The basis for
judging the return of the bus voltage to normal is that the bus voltage is normal and the duration exceeds the set
time of 11-61.
If 11-59=2, during an instantaneous power failure or a sudden drop in voltage, the inverter decelerates until it
stops.
Running frequency
Bus Voltage
11-59=1
:
Deceleration
Normal
running
Judgment voltage of
instantaneous power
failure
11-62
Instantaneous power
failure action pause
judgment voltage
11-60
Running frequency
Judgment time of instantaneous
power failure voltage rise
11-61
11-59=2
:
Decelerate to stop
Stop
acceleration/
deceleration
Deceleration
time 4
Stop
acceleration/
deceleration
Normal
running
Normal
running
Stop
acceleration/
deceleration
Deceleration
time 4
Figure 5-28 Schematic diagram of instantaneous power failure
Summary of Contents for S3100E Series
Page 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Page 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...