64
Inverter temperature rise
Low
→
High
Leakage current
Small
→
Large
External radiation interference
Small
→
Large
The factory setting of carrier frequency is different according to different power models. The user can modify it as
needed, but it should be noted that if the carrier frequency is set higher than the factory value, it will cause the
temperature rise of the inverter radiator to increase. At this time, the user needs to derate the inverter, otherwise
the inverter will be in danger of overheating.
00-11
Parameter initialization
Factory setting
0
Setting range
0
No operation
1
Restore factory parameters, excluding motor parameters
2
Clear record information
1. Restore the factory settings, most of the inverter parameters are restored to the factory values, but the motor
parameters, frequency command decimal point (00-25), fault record information, cumulative running time (08-11),
cumulative power-on time ( 08-13), the cumulative power consumption (08-14) does not recover.
2. Clear record information
Clear the inverter fault record information, cumulative running time (08-11), cumulative power-on time (08-13),
cumulative power consumption (08-14).
Note: The parameter value automatically returns to 0 after the operation is completed.
00-12
Carrier frequency adjusts with temperature
Factory setting
1
Setting range
0
no
1
yes
The carrier frequency is adjusted with the temperature. When the inverter detects that the radiator temperature is
high, the carrier frequency is automatically reduced to prevent the inverter temperature from rising too high and
reduce the overheating alarm. When the temperature of the radiator drops, the carrier frequency automatically
returns to the set value.
00-14
Auxiliary frequency source Y selection
(Refer to 00-02)
Factory setting
0
Setting range
0
Digital setting (keyboard given frequency 00-06, UP /DOWN can be
modified)
1
AVI1
2
AVI2/ACI
3
Reserved
4
Multi-speed command
5
PID control
6
Communication setting
7
Simple PLC
8
Panel potentiometer
9
Pulse setting (MI5)
When the auxiliary frequency source is used independently as the frequency reference channel (that is, the
frequency source selection is switched to Y), the method of use is the same as the main frequency source X. You
can refer to the 00-02 instructions.
Summary of Contents for S3100E Series
Page 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Page 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...