![Savch S3100E Series User Manual Download Page 60](http://html.mh-extra.com/html/savch/s3100e-series/s3100e-series_user-manual_1203759060.webp)
56
12 Serial communication parameters
indicates that the parameters can be set during operation
Parame
ter
Parameter function
Setting range
Factory
setting
12-00
Local address
1
~
247
,
0 is broadcast address
1
12-01
Baud rate
Single digit:modbus
0:300bps
1:600bps
2:1200bps
3:2400bps
4:4800bps
5:9600bps
6:19200bps
7:38400bps
8:57600bps
9:115200bps
0005
12-02
Data formate
0:No checking(8-N-1)
1:Even parity checking(8-E-1)
2:Odd parity checking(8-O-1)
3:No checking(8-N-2)
0
12-03
Communication response delay
0ms
~
20ms
2
12-04
Communication timeout
0.0(invalid)
,
0.1s
~
60.0s
0
12-05
Reserved
12-06
Communication reading current
resolution
0:0.01A
1:0.1A
0
13 Wobble frequency counting parameters
indicates that the parameters can be set during operation
Parame
ter
Parameter function
Setting range
Factory
setting
13-00
Wobble setting mode
0:
Relative to center frequency
1:Relative to Max frequency
0
13-01
Wobble amplitude
0.0%
~
100.0%
0.0%
13-02
Jump frequency amplitude
0.0%
~
50.0%
0.0%
13-03
Wobble frequency cycle
0.1s
~
3000.0s
10.0s
13-04
Wobble triangle wave rise time
0.1%
~
100.0%
50.0%
13-05
Set length
0m
~
65535m
1000m
13-06
Actual Length
0m
~
65535m
0m
13-07
Pulses per meter
0.1
~
6553.5
100.0
13-08
Set count value
1
~
65535
1000
13-09
Designated count value
1
~
65535
1000
Summary of Contents for S3100E Series
Page 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Page 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Page 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Page 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...