Diagnostic Test #2 - Signal Quality
The purpose of Diagnostic #2 is to check the voltage
level of the batteries on a battery-powered clock.
Diagnostic #2 may be enabled by pressing the MECH SW
button twice. If the clock is performing this diagnostic,
then a green LED on the back will flash twice every
three seconds. The output of the test is displayed by the
second hand.
Some examples.
Second hand is on 2, the battery level is 2.2V
Second hand is on 5, the battery level is 2.5V
Second hand is on 9, the battery level is 2.9V
Second hand is on 10, the battery level is 3.0V
Second hand is on 11, the battery level is more
than 3.0V
The purpose of Diagnostic #3 is to bring the clock back to 12:00:00.
Diagnostic #3 may be enabled by pressing the MECH SW button three times. If the SAW clock is
performing this diagnostic, then a green LED on the back will flash three times with a one second break
between each flash. The LED will continue to flash green until the diagnostic is complete. The clock will
confirm that the diagnostic is complete when the LED shines a different color.
If the LED is flashing red:
If the LED is a solid green, the test was completed successfully.
At the end of Diagnostic three, the clock hands will be set to 12:00:00. The clock will not resume normal
operation until the power has been recycled.
NUMBER OF FLASHES
1,2
3,4,5
6,7,8
ERROR MESSAGE
Error detected in second hand. Confirm that hands are not hitting each other, then repeat the test.
Error detected in the minute or hour hand. Confirm that hands are not hitting each other,
then repeat the test.
Call tech support. (+1) 215.322.6063
Diagnostic Test #3 - Full Mechanical Test
Red
Green
MECH SW
All Other Clocks
WIFI SW