SA
Select Alternate
FORMAT
SA [terminator]
EXPLANATION
After execution of the SA command, a character set designated by the CA command is used for
printing. This is effective until the standard character set is selected by the SS command or by
[SI]CHR$(15), or by using the DF or IN command to reset the plotter In print mode, the alter
nate character set can be selected by [SO]CHR$( 14).
This command requires no parameter. For its relation to the CS, CA and SS commands, refer to
"3.6 2 Character Sets” in Chapter 3.
EXAMPLE
10 '
*** "SA" COMMAND ***
20 OPEN "LPT1:" AS #1
30 PRINT #1,"IN;SP1;PA1000,1000;”
40 PRINT #1,"CS0;CA7;"
50 PRINT #1,"SS; "
60 PRINT #1,"LBy=";CHR$(3)
70 PRINT #1,"SA;"
80 PRINT #1 ,"LB";CHR$(120);CHR$(3)
90 PRINT
#
1
,
"
S
S
;
100 PRINT #1,"LBx+l";CHR$(3)
110 PRINT #1,"SP0;"
y = 1/2x + 1
Fig. SA-1
SC
Scale
FORMAT
SC XminfXmax,Ymin,Ymax [terminator]
SC [terminator]
3-55