Move
M
• FORMAT
Mx,y
PARAMETER RANGE
- 3 2 7 6 8 .0000 to + 3276 7.4 99 9
EXPLANATION
Moves the pen in the pen-up status to the point specified by the coordinate (x,y) All coordinates
are absolute coordinates and any number of coordinates may be specified in the form (x coor
dinate, y coordinate). Parameters must be in the range - 32768.0000 to + 3 27 6 7.4 99 9 and
decimal fractions are rounded up or down to the nearest integer. The “ + " sign may be omitted.
If a parameter outside the range is specified, if no parameter is specified, or if only one
parameter is specified, an error occurs.
It an odd number of parameters (3 or more) has been specified, the pairs of parameters are ex
ecuted in sequence and the last odd parameter results in an error.
However, if parameters are specified outside the effective plotting area but within the range of
- 32768.0000 to + 327 6 7.4 99 9 9, the pen will not move. When the processed line data is
within the effective plotting area, the pen will again start to move correctly.
EXAMPLE
10 '
*** ”M" COMMAND ***
20 LPRINT "M0,1000,1000,1000,1000,0,0,0"
(
0
.
1000
)
(
1000
,
1000
)
(
0
.
0
)
(
1000
,
0
)
It move in pen-up status.