example
10 ' * * * F T C O M M A N D * * *
20 O P E N " L P T 1 :" AS #1
20 P R I N T # 1 , " S P 1 ; P T 0 . 3 ; "
40 PRINT #1 ,"PA500,1000;"
50 PRINT #1," F T 1 ,0,0;"
60 P R I N T # 1 ," R R 5 0 0 ,500; "
70 PRINT # 1 , "PA1000,1000;"
80 PRINT # 1 , " F T 4 ,100,45;"
90 PRINT #1,"RR500,500;"
100 PRINT #1,"SP0;"
Fig. FT-1
IM
Input Mask
f o r m a t
IM error mask value [terminator]
IM [terminator]
EXPLANATION
The error mask value is the sum of the error mask bit values (the numbers in Table IM-1 i of the er
rors to be determined. If
a
set bit error occurs, the ERROR LED on the operation panel will flash.
For example, the standard error mask value 223 (128 + 6 4 + 16 + 8 + 4 + 2 + 1) will cause the ER
ROR LED to flash when an error other than Error N o.6 occurs.
Since Error No.4, No.7 and No.8 are not used, an error mask value of 23 (which excludes these
three) means the same as the standard set value 223.
Error mask bit value
Error No.
Meaning
1
1
Unrecognizable command issued
2
2
Wrong number of parameters
4
3
Parameter out of range
8
4
Unused
16
5
Unusable character designated
32
6
Coordinate overflow
64
7
Unused
128
8
Unused
Table IM-1