EXAMPLE
10 '
*** "OD" C O M M A N D ***
20 O P E N " C O M 1 : 9 6 0 0 , N , 8 , 1 " AS #1
30 P RI N T # 1 , " D P ; "
40
P R IN T "Press E N T E R key, then press R E T U R N key.
50 INPUT A
60 P RI N T # 1 , " O D ; "
70 INPUT # 1 ,X,Y,P
80 P R IN T "X= " ; X ; "
Y ="; Y ; "
UD/ = " ; P
90 P R IN T # 1 , " D C ;"
Note: The digitize command is only effective with a serial connection. If this command is used
with a parallel connection, the computer will be unable to receive the data output by the
plotter and may not execute any succeeding commands. If this should happen, switch
the plotter power OFF and ON once to return to the initial condition.
OE
Output Error
(For serial connection only)
OE [terminator]
EXPLANATION
When the OE command is received, the plotter is ready to output an error code in the following
ASCII code.
Error code [TERM]
[TERM] is an output terminator for the RS-232C interface. For details, refer to “ 5.4 Devine Con
trol Command ESC.M’’ in Chapter 5.
When the output is completed, bit 5 of the plotter status byte is cleared and the error indicator
goes out.
The error codes are defined in Table OE-1.
Bit value
Error No.
Meaning
0
0
No error
1
1
Unrecognizable command issued
2
2
Wrong number of parameters
4
3
Unusable parameter
8
4
Unused
16
5
Unusable character set designated
32
6
Coordinate overflow
64
7
Unused
128
8
Unused
Table OE-1
3-41
Summary of Contents for DXY-1100
Page 1: ...X Y PLOTTER DXY 1300 1200 1100 Roland DIGITAL GROUP ...
Page 2: ......
Page 3: ...X Y PLOTTER DXY 1300 1200 1100 COMMAND REFERENCE MANUAL c ...
Page 4: ......
Page 44: ......
Page 140: ......
Page 142: ......
Page 144: ......
Page 148: ......
Page 154: ......
Page 155: ......
Page 156: ...Roland DIGITAL GROUP ...