Manual
Double Sheet Detector-series I20
B0069991 / Rev. 1.7
System description
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
31
In addition to the selection by sensor number (see chapter 13 “System Configuration - number of
sensors"), the following combinations of selections are available:
Combinations for 2 channel system
Combinations for 4 channel system
Sensor 1
Sensor 2
Sensor 1 + Sensor 2
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 1 + Sensor 2
Sensor 1 + Sensor 3
Sensor 1 + Sensor 4
Sensor 2 + Sensor 3
Sensor 2 + Sensor 4
Sensor 3 + Sensor 4
Sensor 1 + Sensor 2 + Sensor 3
Sensor 1 + Sensor 2 + Sensor 4
Sensor 1 + Sensor 3 + Sensor 4
Sensor 2 + Sensor 3 + Sensor 4
Sensor 1 + Sensor 2 + Sensor 3 + Sensor 4
1,5 mm
1,5 mm
0,6 mm
0,6 mm
Program Thickness Sensor
1
1,0 mm
1, 2, 3, 4
PLC
1. measure Pr.1
2. evaluate result Pr.1