7.10
Data backup
For better prevention off loss of data, a data backup procedure is available for the system
configuration and the parameter sets. The backup is made via the upper USB interface on the front
panel. The secured data can be transferred to spare units in case of exchange after a failure.
The data backup is accomplished with the RPP7 software available from ROLAND
(for Win2000 / XP / Vista).
The data backup procedure can be selected in the menu configuration. The following menu is
displayed during the data backup.
Fig. 96: Status of data backup
For backup of data, the upper USB slot on the front panel must be used.
7.11 Firmware
update
Roland systems are permanently enhanced. In order to use new functions, firmware update is
required.
For firmware update use the
lower
front panel USB slot.
Note
The firmware update may be performed only by qualified personnel.
On the PC used for firmware update, the actual RPP7 software must be
installed, and the desired firmware version (.bin file) must be available.
The RPP7 software can be found on the supplied CD.
For performing the update, connect the Double Sheet Detector to the
lower
front panel USB
interface of the PC, using the supplied cable. Then select “Firmware Update” in the configuration
mode.
Fig. 97: Indication for activating firmware update
Parameter backup
active
FIRMWARE UPDATE
connect USB(FLASH)