Manual
Double Sheet Detector-series I20
Start-up
B0069991 / Rev. 1.7
92
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
System parameter 12:
Specifying the type of sensor.
Fig. 83: Specifying the type of sensor
Possible choices:
• IS42-30GS / IE42-30GS (also for ISQ42S / IEQ42S)
• IS20-30GS / IE20-30GS
• ISQ160S / IEQ160S
System parameter 13:
Specifying the settling time.
Fig. 84: Specifying the settling time
The settling time is entered here, which will be preset as “desired” settling time in the “Clear
program parameters” step. This time will be used if the existing settling time is lost due to deletion
of the program parameters and a usable setting is no longer available.
System parameter 14: Adjusting the measuring mode.
Fig. 85: Adjusting the measuring mode
Possible measurement modes:
•
external single:
The system measures
once
if the “Measurement start“ signal is applied
via the external PLC input. Each measurement must initiated
separately. The notes in chapter 6.3.2 „timing diagram single
measurement“ must be observed.
•
demonstration:
This mode of operation is intended for equipment demonstrations, but
not for normal process operation. The system executes measurements
continuously.
•
external continuous:
The system executes measurements, as long as
the “Measurement start“ signal is applied via the external PLC input.
external special:
As for “external continuous”, but: The highest value reached during a
measurement cycle is displayed and maintained at the outputs until a
new measurement is started.
This also applies for the outputs 0-1-2-Warning.
System Parameter: 12
sensor type
IS42-30 / IE42-30
System Parameter: 13
default settlingTime
250 ms
System Parameter: 14
measure mode
extern continuous