7.7
Program parameters
7.7.1
Program parameters for the double sheet detection
This menu structure is valid for the system types a – f (For details refer to chapter 3.2)
The program parameters contain the information required for the various measurement programs.
For accessing the program parameters, select the mode “configuration program parameter“ and
confirm with
ENTER
.
Program parameter 1:
Selecting the measuring program to be configured.
Fig. 38: Selecting the program to be configured
Here the measuring program (1-255) to be configured is selected. All following adjustments apply
to the selected program.
Program parameter 2:
Selecting the sensors to be used for measurement.
Fig. 39: Sensor number / Sequence
Here the sensor pair /sensor pairs is / are selected, which are to be used for measurement.
Possible choices:
• 1 / 2 / 3 / 4
• 1+2 / 1+3 / 1+4 / 2+3 / 2+4 / 3+4
• 1+2+3 / 1+2+4 / 1+3+4 / 2+3+4 / 1+2+3+4
Program parameter 3:
Specifying the nominal thickness and material of the sheet to be
measured in mm or inch.
This parameter is only in the operating mode
„Standard” available.
Fig. 40: Adjusting the nominal thickness
Here the nominal thickness of the sheet to be measured is specified. Normally, the nominal
thickness is the sheet thickness used for Teach-In.
Attention
A change of the nominal thickness deletes the values
determined during Teach-In. A new Teach-In is required.
Program Parameter: 1
Program Number
1
Program Parameter: 2
Sensor no./Sequence
Program Parameter: 3
nominal thickness
0.90mm