7.8 Adjustment
parameters
Adjustment parameters are parameters, which are only valid for this individual system; they cannot
be transferred to other systems.
Adjustment parameter 1:
Zero adjust
The Zero adjust procedure must be performed at commissioning and after having exchanged a
sensor.
Attention
Before performing a Zero adjust procedure, verify carefully that no
sheet is in the sensor gap.
Fig. 67: Status of Zero adjust
Possible choices:
• no:
no Zero adjust to be performed.
• all / yes:
All sensors are zero adjusted at the same time.
During the zero adjust the following message is shown:
Maximum time 150 sec.
Fig. 68: Display during zero adjust
Note
Fault messages are described in the chapter “9 Fault messages“.
When the zero adjust is completed, the following message appears:
Fig. 69: Zero adjust successfully completed
The zero adjust is now completed.
Adjust Parameter: 1
Zero adjust
no
Adjust Parameter: 1
Zero adjust
Zero adjust active
Adjust Parameter: 1
Zero adjust
no