Manual
Double Sheet Detector-series I20
B0069991 / Rev. 1.7
Start-up
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
69
7 Start-up
7.1
Initially applying power to the system
The I20 is designed for an operating voltage of 24 VDC (+6 V / -4 V). This voltage is to be checked
before applying power. The control unit is automatically switched on by applying the power.
After applying power, the type of system and the version number are briefly displayed. Then the
system switches into that measurement menu, which was active before the unit was switched off.
If the equipment does not power up, the fuse should be checked.
7.2 Start
screen
After applying the supply voltage to the system, the start screen will be shown until the unit has
initialized.
Fig. 28: Start screen
It shows the type of system and the software version.
After the control unit is fully operational, the Start screen is replaced by the operations screen.
ROLAND ELECTRONIC
I20
SV: 21