Signal range for 0-sheet
Signal range for 1-sheet
Signal range for 2-sheet
Upper switching threshold
Lower switching threshold
a
b
c
TU
TL
Fig. 10: Visualization of switching thresholds
The switching thresholds should be adjusted corresponding to the application.
“Nom./curr. settling time”
Defines the time within the system must achieve a stable measurement result.
For details refer to chapter 3.7.2.
“Teach-In Part A“
The unit calibrates part A to 100%.
The calibration applies only to the currently selected program.
“Teach-In Part B“
The unit calibrates part B to 200%.
The calibration applies only to the currently selected program.