MQ03-Alarm - Installer Manual 

V 1.2 

 

 

 

 

Summary of Contents for MQ03-Alarm

Page 1: ...d 1 Kukush Str building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd 1 Kukush Str building M8 Sofia 1309 Bulgaria Web Site www m2mservices com M2M Services Ltd MQ03 Alarm Installer Manual V 1 2 ...

Page 2: ...ring detectors 3 SMARTEnroll self learning zones 3 Using the wireless keyfobs 4 Pairing a wireless keyfob 4 Deleting a wireless keyfob 4 Configuring the MQ03 Alarm 5 General settings of MQ03 Alarm 5 General settings of the partition 5 Configuring the zones 6 Zone types 6 ...

Page 3: ... the alarm panel The tamper can be connected to a zone configured as 24h tamper SMARTEnroll self learning zones The MQ03 Alarm panel supports SMARTEnroll feature preconfigured settings and self learning zones which in most cases eliminate the need of initial programming of the alarm panel This simplifies the installation process in the most commonly used scenario when only instant zones with no en...

Page 4: ... 2 seconds and then it will start blinking fast This shows that the keyfob has been paired and the procedure was successful You need to repeat this procedure for each additional wireless keyfob separately NOTE 1 If after pressing the white pairing button the RF transceiver does not receive signal from the wireless keyfob within 30 seconds the pairing procedure will be automatically canceled 2 You ...

Page 5: ... the delay in seconds after which the device will report the mains power outage Configuring the Battery level thresholds In section Battery field Battery low you can set a low voltage threshold under which the alarm panel will send Low Battery event In the filed Battery Critical Low you can set even lower voltage threshold and if the battery voltage goes under this level it will be considered as c...

Page 6: ...n the alarm cycle time expires the zone restore event will be reported only when the zone is really restored In addition even when there was a restore during the alarm cycle this restore will not be reported until the expiration of the alarm cycle time or until the partition is disarmed Zone types Entry Exit zone The Entry Exit zones can be violated during the entry exit time delay without causing...

Page 7: ...t zone is violated In this case the alarm panel sends a ContactID event E 374 Exit Error in Zone N reporting the first of all the violated zones which prevent the panel from arming Follow STAY zone This is a Follow zone that is not monitored when the panel is partially armed STAY Arm Instant STAY zone This is an Instant zone that is not monitored when the panel is partially armed STAY Arm ...