Quick Start Guide 1321.3066.02 ─ 05
Table 6-6: Signal generator settings (e.g. R&S SMU)
Frequency
890 MHz
Level
0 dBm
Modulation
GSM, one timeslot activated
The measurement is based on the setting in the example above for measuring
the power of the GSM during the activation phase.
1. Switch off the power measurement.
a) Press the MEAS key.
b) Press the "All Functions Off" softkey.
2. Increase the time resolution to 100 µs.
a) Press the SWEEP key.
b) Press the "Sweeptime Manual" softkey and enter
100 µs
.
3. Using the trigger softkey, shift the rising edge of the GSM burst to the center
of the screen.
a) Press the TRIG key.
b) Press the "Trigger Offset" softkey.
Measurements in Zero Span