NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
80
User Manual 1178.5689.02 ─ 06
.......................................................................................... 80
Max. No. Repetitions Rmax
Specifies the maximum number of repetitions R
max
for NPDCCH transmissions used in
the cell.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:MXNRep
No. Repetitions
Specifies the number of repetitions R for actual NPDCCH transmissions related to
R
max
. The absolute number of NPDCCH repetitions in a subframe is also displayed.
The transmission is repeated over consecutive NB-IoT downlink subframes.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:NREP
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:NRRepr?
Start SF
Specifies NPDCCH starting position as a subframe. Start SF results in the displayed
periodicity of NPDCCH transmissions.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:STSF
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:PERiod?
Offset
Shifts the start SF related to R
max
value. Absolute value in subframes is displayed for
information.
Remote command:
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:OFFSt
CONFigure:NIOT:SIGN<i>:CONNection:NPDCch:SFOFfst?
2.3.11.7
Miscellaneous Connection Settings, Part 2
Access: "Config" hotkey > "Connection" > bottom of the "Connection" section.