NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
166
User Manual 1178.5689.02 ─ 06
Manual operation:
See
"Release Assistance Indication"
CONFigure:NIOT:SIGN<i>:CONNection:DIT:ENABle
<ENable>
Enables/disables the data inactivity timer.
Parameters:
<ENable>
OFF | ON
*RST:
OFF
Example:
See
Configuring General Connection Settings
Firmware/Software:
V3.7.50
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:DIT:TIMer
<Timer>
Specifies the data inactivity timer.
Parameters:
<Timer>
1 | 2 | 3 | 5 | 7 | 10 | 15 | 20 | 40 | 50 | 60 | 80 | 100 | 120 | 150 |
180
*RST:
1
Default unit: s
Example:
See
Configuring General Connection Settings
Firmware/Software:
V3.7.50
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:STYPe
<Type>
Selects the scheduling type.
Parameters:
<Type>
ULRMc | DLRMc | UDEF
ULRMc
: UL RMC
DLRMc
: DL RMC
UDEF
: user-defined scheduling
*RST:
ULRM
Example:
See
Firmware/Software:
V3.7.20
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:DPCYcle
<Cycle>
Selects the cell-specific default paging cycle.
Command Reference