"Magnitude Error"
●
"Phase Error"
Each of these single-preamble views shows a diagram and a statistical overview of
results.
Figure 4-6: Error Vector Magnitude view
The diagram shows the EVM / magnitude error / phase error in all 20 symbols of the
preamble. The values are RMS-averaged over the samples in each symbol.
For a description of the table rows, see
Chapter 4.3.2.6, "View TX Measurement"
For table columns and other elements, refer to
Chapter 4.3.2.9, "Common View Ele-
For query of the diagram contents via remote control, see:
●
FETCh:NIOT:MEAS<i>:PRACh:TRACe:EVM:CURRent?
●
FETCh:NIOT:MEAS<i>:PRACh:TRACe:MERRor:CURRent?
●
FETCh:NIOT:MEAS<i>:PRACh:TRACe:PERRor:CURRent?
4.3.2.3
Views EVM vs Preamble, Power vs Preamble
This section applies to the following detailed views:
●
"Error Vector Magnitude vs Preamble"
●
"Power vs Preamble"
GUI Reference