NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
59
User Manual 1178.5689.02 ─ 06
General Physical Cell Settings
................................................................................59
In-Band / Guard-Band Configuration
.......................................................................60
...........................................................................................62
2.3.9.1
General Physical Cell Settings
Access: "Config" hotkey > "Physical Cell Setup" > top of the "Physical Cell Setup" sec-
tion.
Figure 2-32: Cell parameters
Duplex Mode
Selects the duplex mode. The current software version supports only FDD, not TDD.
Remote command:
UL Subcarrier Spacing
Selects the uplink subcarrier spacing (3.75 kHz or 15 kHz).
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:SCSPacing
Physical Cell ID
The cell ID is used for the generation of synchronization signals. During cell search,
the UE determines the cell ID from the secondary synchronization signal.
The physical cell ID can be set independent of the cell identifier sent to the UE via
broadcast (see
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:PCID
Operation Mode
Selects the operation mode. The UE is informed about this setting via the "operation-
ModeInfo" in the master information block (MIB).
For the "Standalone Mode", there are no specific additional settings. For the other
modes, configure also the "In-Band / Guard-Band" settings.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:OPERmode
GUI Reference
深圳德标仪器