NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
66
User Manual 1178.5689.02 ─ 06
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:RESelection:QUALity
T Reselection
Sets the time hysteresis for the cell reselection algorithm.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:RESelection:TIME
2.3.10.3
Identity
Access: "Config" hotkey > "Network" > "Identity" section.
This section configures identities of the simulated radio network. The values are trans-
ferred to the UE under test via broadcast.
Figure 2-37: Network identity settings
................................................................................................ 66
MCC
Specifies the three-digit mobile country code (MCC).
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:MCC
MNC
Specifies the mobile network code (MNC). A two or three-digit MNC can be set.
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:MNC
CONFigure:NIOT:SIGN<i>:CELL:MNC:DIGits
TAC
Specifies the tracking area code (TAC).
Remote command:
CONFigure:NIOT:SIGN<i>:CELL:TAC
E-UTRAN Cell Identifier
Specifies the E-UTRAN cell identifier, unique within a PLMN. It is sent to the UE via
broadcast and can be set independent of the physical cell ID (see
GUI Reference