NB-IoT Signaling
R&S
®
CMW-KM300/-KS300
175
User Manual 1178.5689.02 ─ 06
<Modulation>
QPSK
Modulation scheme
<TransBlockSize>
Transport block size
Example:
See
Configuring User-Defined Channels
Usage:
Query only
Firmware/Software:
V3.7.20, V3.7.60: added <MCSindex> MI13
Manual operation:
See
CONFigure:NIOT:SIGN<i>:CONNection:UDEFined:FORMat?
Queries scheduling parameters for UL user-defined scheduling for NPUSCH format 2.
These settings are not configurable.
Return values:
<Subcarriers>
SC1
Number of subcarriers
<StartSubcarrier>
Range:
0 to 45
<Modulation>
BPSK
<ResourceUnits>
NRU01
Number of resource units
<Repetitions>
NR1 | NR2 | NR4 | NR8 | NR16 | NR32 | NR64 | NR128 |
NR192 | NR256 | NR384 | NR512 | NR768 | NR1K | NR1536 |
NR2K
Number of NPUSCH repetitions: 1, 2, 4, ..., 512, 768, 1024,
1536, 2048
Usage:
Query only
Firmware/Software:
V3.7.20, V3.7.50: added <Repetitions> NR192, NR256, NR384,
NR512, NR768, NR1K, NR1536, NR2K
Manual operation:
See
2.5.12.5
HARQ Settings
The following commands configure HARQ connection settings.
CONFigure:NIOT:SIGN<i>:CONNection:HARQen
............................................................. 175
CONFigure:NIOT:SIGN<i>:CONNection:MAXNumtr
.......................................................... 176
CONFigure:NIOT:SIGN<i>:CONNection:NUMHqpc
........................................................... 176
CONFigure:NIOT:SIGN<i>:CONNection:HARQen
<HarqEnable>
Enables or disables HARQ for downlink transmissions.
Command Reference
深圳德标仪器
135-1095-0799